Signal Name | Description | Condition | Impact |
---|---|---|---|
Track will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine.
|
Track position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
|
Track motor will stop moving
|
|
Pitch will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine. AlertLog contains uncalibrated reason.
|
Pitch position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
|
Pitch motor will stop moving
|
|
The 2nd Row Left Seat Body Controller (BCS2L) detects the first row seat is not calibrated.
|
The BCS2L detects the first row seat is not calibrated.
|
Easy entry for the second row seat may be unavailable or may not function as expected.
|
|
None
|
at least one of lumbarHPosition, lumbarVPosition, or headrestPosition signals is -2048
|
Second row seat behind cannot do easy entry
|
|
None
|
The car is in a moving gear, and the track is unlatched
|
Occupant safety is impacted
|
|
The second row left seat heater is not heating as expected.
|
The seat heater duty cycle was set at 100% for 30 minutes.
|
Second row left seat heater will be unavailable.
|
|
The third row left seat heater is not heating as expected.
|
The seat heater duty cycle was set at 100% for 30 minutes.
|
Third row left seat heater will be unavailable.
|
|
The second row center seat heater is not heating as expected.
|
The seat heater duty cycle was set at 100% for 30 minutes.
|
Second row center seat heater will be unavailable.
|
|
The second row right seat heater is not heating as expected.
|
The seat heater duty cycle was set at 100% for 30 minutes.
|
Second row right seat heater will be unavailable.
|
|
Seat temperature sensor may be disconnected, shorted, or faulted.
|
The temperature sensor senses a fault and is either shorted or disconnected
|
The 3rd row seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 2nd row seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 3rd row seat heater may be disabled
|
|
Reconnect track sensor.
|
The track sensor senses a disconnect
|
Seat calibration will not work
|
|
The fold flat switch remains activated for a duration extending 20 seconds without interruption, suggesting continued pressing despite initial intentions having presumably already been fulfilled.
|
The fold flat switch remains activated for a duration extending 20 seconds without interruption.
|
The features the fold flat switch control may be disabled.
|
|
The third row right seat heater is not heating as expected.
|
The seat heater duty cycle was set at 100% for 30 minutes.
|
Third row right seat heater will be unavailable.
|
|
The right second row seat backrest is unlatched.
|
The vehicle is not in Park, the backrest is unlatched, the track is latched, and the right second row seat is occupied.
|
The backrest may move unexpectedly because it is unlatched.
|
|
Seat install mode is enabled.
|
Seat install mode is enabled via UDS/ODIN
|
The second row seat will have all track restrictions removed and pitch movement locked out
|
|
This message contains separate signals for each watchdog reset source.
|
A watchdog (external or internal) was not serviced in time.
|
These are the repercussions of the alert being set
|
|
Undervoltage detection by the CPU can set this alert.
|
Sudden power loss.
|
These are the repercussions of the alert being set
|
|
Not Available
|
Failure of a software assertion.
|
These are the repercussions of the alert being set
|