BCS2C_w042_trackMotorLogicTempUV
Description
3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels.
Condition
Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V
Clear Condition
Any of the following conditions go away: overtemperature, undervoltage, incorrect logic levels
Potential Impact
If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service;service-fix
Models
Model S 2012-2020;Model X 2015-2020