Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
This alert is reported by the PWMDriverCD_TC3x component when the control cycle and tasking cycle synchronization mismatch.
|
EPAS application component PWM monitor detected failure (control cycle and tasking cycle synchronization mismatch).
|
EPAS reset. If reset more than 5 times then EPAS full loss of assist.
|
|
This alert is reported by the GDUDriverHAL_A4918 (GDUH) component when SPI buffer overflow, DMA status is not OK.
|
EPAS ECU GDU device monitor detected failure (serial communication buffer overflow).
|
EPAS reset
|
|
This alert is reported by the DeadlineMonitor_R12 (DM) component when at least one of the monitored tasks didn't finish or finished multiple times during it's configured time frame.
|
EPAS application operating system monitor detected task timeout or task finished multiple times during it's configured time frame on Core0.
|
EPAS reset
|
|
x19 is a diagnostic overview register, registers 1A to 1E provides additional granularity for EPAS digital current sensor (DCS) fault concerns.
|
Any bit is set from the EPAS DCS x19 register
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
Electronic Power Assist Steering (EPAS) digital current sensor (DCS) register CREGx or CTUBx voltage less than expected.
|
Internal digital current sensor (DCS) CBoot flag is set
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
Gate drive SPI communication error.
|
Gate drive SPI communication errors
|
Reduced steering assist
|
|
Torque sensor 2 signal invalid.
|
Invalid Torque sensor 2 signal received by EPAS
|
Steering assist reduced and EAC inhibited
|
|
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU internal failure. (Memory Built-In-SelfTest failed).
|
EPAS microcontroller memory (M)BIST failed at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU internal failure (The Secondary Monitor and Standby SMU Built in Self Test failed).
|
EPAS microcontroller (MON)BIST failed (SecondaryMonitor versus Standby SMU) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the SoftwareVersionChecker_R12 (SVC) component when the primary and secondary side SW version is different, reflashing is needed.
|
EPAS primary and secondary side SW versions are incompatible.
|
EPAS full loss of assist.
|
|
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU failure. Logic built-in self-test failed.
|
EPAS Microcontroller built-in self tests (BIST) that the SW runs after reset failed for 3 consecutive times.
|
EPAS full loss of assist.
|
|
This alert is reported by the TemperatureSensorMCUCore_TC3x (TSMC) component when there is a MCU internal failure (temperature sensor or other failure which generates uneven heating of the MCU).
|
EPAS uC core and power supply temperatures exceed tolerated difference.
|
EPAS full loss of assist.
|
|
This alert is reported by the SwResetHandler_R12 (SWRH) component when there is a RAM failure: the stored error is not visible OR SW systematic failure: error not stored or not handled.
|
EPAS could not retrieve the reset reason store error in RAM.
|
EPAS full loss of assist. EPAS is unable to establish why the SW has been started.
|
|
This alert is reported by the StartupCauseProvider_R12 (SCP) component when all received causes are unknown startup causes and the determined startup cause is UNKNOWN.
|
EPAS detected unknown startup cause at startup.
|
EPAS full loss of assist. EPAS is unable to establish why the SW has been started.
|
|
This alert is reported by the StartupCauseProvider_R12 (SCP) component in case, at least one of the possible reset causes is not available after the provision time has elapsed.
|
EPAS has incomplete list of reset causes at startup.
|
EPAS has lost info about reset causes.
|
|
This alert is reported by the ParameterSelectorProvider_R12 (PSP) component when Powerpack (PWP), Common (COM), or ECU parameter selection is not successful.
|
EPAS ECU PowerPack (PWP) ID is not compatible with the given software due to ECU parameter set.
|
EPAS full loss of assist.
|
|
This alert is reported by the ADCDriverCD_TC3x component when Analog-Digital Converter (ADC) multiplexer testing failed, the root cause also can be reference problems or short-to-GND/short-to-supply type pin errors.
|
Measured REF voltage or Measured GND voltage are out of range.
|
EPAS full loss of assist.
|
|
This alert is reported by the ADCDriverCD_TC3x component when Analog-Digital Converter (ADC) calibration cannot be started, timeout reached. MCU failure.
|
EPAS uC peripheral ADC self calibration timeout at startup.
|
EPAS full loss of assist. EPAS ADC is considered inoperable.
|
|
Electric Power Assisted Steering (EPAS) reports unexpected error between internal angle sensor and steering column control module (SCCM) angle sensor.
|
The steering system detects divergence between its internal angle sensor and external angle sensor greater than 30 degrees.
|
Angle measurement divergence could indicate steering system belt slip or other mechanical failure.
|
|
Electric Power Assisted Steering (EPAS) reports its secondary Electronic Control Unit (ECU) activated External Angle Control (EAC).
|
The EPAS secondary ECU activates EAC due to a condition affecting the primary ECU.
|
Backup EAC is active due to a detected condition on the primary steering ECU.
|