Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
This alert is reported by the ExternalPowerManager_A8140x (EPM) component in case of V5P2 Undervoltage and Overvoltage.
|
EPAS ECU SBC device monitor reports failure (internal voltages) at runtime.
|
EPAS full loss of assist.
|
|
This alert is reported by the SystemBasisChipManager_A8140x (SBCM) component when Built-In-Selftest is failed.
|
EPAS ECU SBC device BIST failure at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the SystemBasisChipHAL_A8140x (SBCH) component when ChipId check is failed - It is SPI-communication related problem.
|
EPAS ECU SBC device monitor reports failure (chip ID, SPI communication) at runtime.
|
EPAS full loss of assist.
|
|
This alert is reported by the SystemBasisChipHAL_A8140x (SBCH) component in case it detects the internal failure of the SBC.
|
EPAS ECU SBC device monitor reports failure (readback not plausible) at runtime.
|
EPAS full loss of assist.
|
|
This alert is reported by the InterCoreSoftwareVersionChecker_R12 (ICSVC) component when Core0 and Core1 SW versions are different.
|
EPAS primary and secondary side core platform SW versions are incompatible.
|
EPAS full loss of assist.
|
|
This alert is reported by the EOL_Provider_R12 (EOLP) component if any of the EOL inverse pair check fail or if the EOL layout version is below the supported version.
|
EPAS uC internal memory (EOL param storage) failure (inverse pair check failed) at startup or incompatible EOL Layout version.
|
EPAS full loss of assist.
|
|
This alert is reported by the ProductionModeSupervisor_R12 (PMS) component when production mode was requested by either the EOL__PLATFORM__PRODUCTION_MODE parameter or not-initialized RAM and the handshake with Core1 was unsuccessful.
|
EPAS production mode requested and the handshake mechanism with Core1 failed.
|
EPAS full loss of assist.
|
|
This alert is reported by the HwResetHandler_TC3x (RSTH) component when the clock frequency is out of range or clock system failure.
|
EPAS uC core detected internal clocking error (clock frequency is out of range or system failure).
|
EPAS full loss of assist.
|
|
This alert is reported by SMUHandler_TC3X (SMUH) component when SMU Core alive test is failed.
|
EPAS uC peripheral (SMU core) alive test failure at startup, before start of OS.
|
EPAS full loss of assist.
|
|
This alert is reported by the SMUHandler_TC3X (SMUH) component when SMU Core Alive test data integrity check fails (comparison with the inverted value).
|
EPAS uC peripheral (SMU) alive test failure (data corruption, inverted value comparison) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a Flash Operation Error OR Command Sequence Error OR Protection Error OR Program Verify Error OR Erase Verify Error OR SRI Bus Address ECC Error OR UCB Original Error.
|
EPAS uC peripheral (DMU_HF) startup checks failure at startup.
|
EPAS full loss of assist.
|
|
This alert is reported when CRC check failed, consistency of non-inited memory sections did not keep during the restart.
|
EPAS uC peripheral (SMU) alive test failure (CRC) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when CRC check failed for its non-initialized.
|
EPAS uC internal memory (BTARC management storage) failure (CRC) for non-initialized data at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the SafetyRelayHAL_R12 (SRH) component if the CRC calculation of the SEC_VAR_SRH_BIST_STATUS memory section is failed or the CRC validity pattern is invalid. During the startup SafetyRelayHAL_R12_RestoreRelays function stores the state of the non-initialized data integrity (corrupted or not) in the SRH_D8037_Status variable and this is evaluated after RTE has been started.
|
EPAS uC internal memory (safety relay management storage) failure (CRC) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when fast restart data has been corrupted.
|
EPAS uC internal memory (BTARC management storage) failure (corrupted information) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by SwResetHandler_R12 (SWRH) component when the ResetReason_Sw structure CRC check is failed.
|
EPAS uC internal memory (startup code management storage) failure (CRC) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by OsErrorHandler_R12 (OSEH) component when the ResetReason_OsError structure CRC check is failed.
|
EPAS uC internal memory (OS reset management storage) failure (CRC) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when the EOL_INTEGRITY in FLASH is wrong.
|
EPAS uC internal memory (EOL param storage) integrity failure at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the HwResetHandler_TC3x (RSTH) when the startup test of the protected memory areas has failed.
|
EPAS microcontroller internal memory (reset management storage) failure (CRC) at startup.
|
EPAS full loss of assist.
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when the CRC mismatch is detected in the non-initialized data.
|
EPAS application component ExceptionHandler detected memory failure (CRC) at startup.
|
EPAS full loss of assist.
|