| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the Secondary Monitor and Standby SMU Built in Self Test failure, MCU failure
|
EPAS secondary monitor and standby SMU BIST timeout
|
EPAS full loss of assist
|
No
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the memory Built-In-SelfTest failed, MCU failure
|
EPAS memory BIST timeout.
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
No
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the memory Built-In-SelfTest failed, errors in the critical memory units. MCU failure
|
EPAS memory BIST found any errors in critical memory units (CPU0, CPU1, DMA).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
No
|
|
|
This alert is reported when the Start-up register check failed: MCU internal error OR SW systematic failure
|
EPAS microcontroller's different registers does not contain the right values before starting the safety functions (CRC doesn't match for the second test fail).
|
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
|
No
|
|
|
This alert is reported by ActuatorManager_R12 (AM) component when there is a GDU failure or current sensing failure
|
GDU failure or current sensing failure. When the GDU_FLAG_LO_CURRENT_MEASUREMENT_AMPLIFIER_DISCONNECTED bit is set in GDUStatus:GduErrorCode.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a bus level MPU violation
|
EPAS application component ExceptionHandler detected exception (bus level MPU violation).
|
EPAS reset
|
No
|
|
|
This alert is reported when ALM7[31] Flash Stored Configuration Error alarm
|
EPAS application component ExceptionHandler detected exception (FSI flashed stored config storage).
|
EPAS reset.
|
No
|
|
|
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a phase current shunt temperature higher than limit or not available
|
EPAS application actuator temperature diagnostics detected overtemperature (phase current shunt).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a DC Bus shunt temperature higher than limit or not available
|
EPAS application actuator temperature diagnostics detected overtemperature (DC bus shunt).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when there is a double bit ECC error in the active pflash and additional ECC errors were found in the same wordline
|
EPAS application component ExceptionHandler detected unrecoverable memory failure (other page PFlash ECC fault).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ExternalPowerManager_A8140x (EPM) component in case indicates if the Boost drive
|
Boost drive is indicated, LG pin does not match the commanded value.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a Flash Operation Error OR Command Sequence Error OR Protection Error OR Program Verify Error OR Erase Verify Error OR SRI Bus Address ECC Error OR UCB Original Error
|
EPAS uC peripheral (DMU_HF) startup checks failure at startup.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ActuatorManager_R12 (AM) component when there is a GDU or GDU-SBC connection problem
|
This alert is no longer used and replaced by EPAST_a085_amGduSwitchOffTestByMcu
|
This alert is no longer used and replaced by EPAST_a085_amGduSwitchOffTestByMcu
|
No
|
|
|
This alert is reported by the DeadlineMonitor_R12 (DM) component when at least one of the monitored tasks didn't finish or finished multiple times during it's configured time frame
|
EPAS application operating system monitor detected task timeout or task finished multiple times during it's configured time frame on Core0.
|
EPAS reset
|
No
|
|
|
This alert is reported when there is a SW systematic failure, faulty error reporting in one of the components (report and error with not supported errorId)
|
EPAS application component ErrorReactionManager detected invalid error message (wrong errorId or messageKind).
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when the CRC mismatch is detected in the non-initialized data
|
EPAS application component ExceptionHandler detected memory failure (CRC) at startup.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the SafetyRelayHAL_R12 (SRH) component if the CRC calculation of the SEC_VAR_SRH_BIST_STATUS memory section is failed or the CRC validity pattern is invalid. During the startup SafetyRelayHAL_R12_RestoreRelays function stores the state of the non-initialized data integrity (corrupted or not) in the SRH_D8037_Status variable and this is evaluated after RTE has been started.
|
EPAS uC internal memory (safety relay management storage) failure (CRC) at startup.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when fast restart data has been corrupted.
|
EPAS uC internal memory (BTARC management storage) failure (corrupted information) at startup.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by the ExternalPowerManager_A8140x (EPM) component in case of V5P2 Undervoltage and Overvoltage.
|
EPAS ECU SBC device monitor reports failure (internal voltages) at runtime.
|
EPAS full loss of assist.
|
No
|
|
|
This alert is reported by SwResetHandler_R12 (SWRH) component when the ResetReason_Sw structure CRC check is failed.
|
EPAS uC internal memory (startup code management storage) failure (CRC) at startup.
|
EPAS full loss of assist.
|
No
|