Alerts

Alerts

Signal Name Description Condition Impact
This alert is reported by the EOL_Provider_R12 (EOLP) component if any of the EOL inverse pair check fail or if the EOL layout version is below the supported version.
EPAS uC internal memory (EOL param storage) failure (inverse pair check failed) at startup or incompatible EOL Layout version.
EPAS full loss of assist.
This alert is reported by the ProductionModeSupervisor_R12 (PMS) component when production mode was requested by either the EOL__PLATFORM__PRODUCTION_MODE parameter or not-initialized RAM and the handshake with Core1 was unsuccessful.
EPAS production mode requested and the handshake mechanism with Core1 failed.
EPAS full loss of assist.
This alert is reported by the HwResetHandler_TC3x (RSTH) component when the clock frequency is out of range or clock system failure.
EPAS uC core detected internal clocking error (clock frequency is out of range or system failure).
EPAS full loss of assist.
This alert is reported by SMUHandler_TC3X (SMUH) component when SMU Core alive test is failed.
EPAS uC peripheral (SMU core) alive test failure at startup, before start of OS.
EPAS full loss of assist.
This alert is reported by the SMUHandler_TC3X (SMUH) component when SMU Core Alive test data integrity check fails (comparison with the inverted value).
EPAS uC peripheral (SMU) alive test failure (data corruption, inverted value comparison) at startup.
EPAS full loss of assist.
This alert is reported when CRC check failed, consistency of non-inited memory sections did not keep during the restart.
EPAS uC peripheral (SMU) alive test failure (CRC) at startup.
EPAS full loss of assist.
This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when CRC check failed for its non-initialized.
EPAS uC internal memory (BTARC management storage) failure (CRC) for non-initialized data at startup.
EPAS full loss of assist.
This alert is reported by the SafetyRelayHAL_R12 (SRH) component if the CRC calculation of the SEC_VAR_SRH_BIST_STATUS memory section is failed or the CRC validity pattern is invalid. During the startup SafetyRelayHAL_R12_RestoreRelays function stores the state of the non-initialized data integrity (corrupted or not) in the SRH_D8037_Status variable and this is evaluated after RTE has been started.
EPAS uC internal memory (safety relay management storage) failure (CRC) at startup.
EPAS full loss of assist.
This alert is reported by the BlackoutTimeAndResetCounter_R12 (BTARC) component when fast restart data has been corrupted.
EPAS uC internal memory (BTARC management storage) failure (corrupted information) at startup.
EPAS full loss of assist.
This alert is reported by SwResetHandler_R12 (SWRH) component when the ResetReason_Sw structure CRC check is failed.
EPAS uC internal memory (startup code management storage) failure (CRC) at startup.
EPAS full loss of assist.
This alert is reported by OsErrorHandler_R12 (OSEH) component when the ResetReason_OsError structure CRC check is failed.
EPAS uC internal memory (OS reset management storage) failure (CRC) at startup.
EPAS full loss of assist.
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when the EOL_INTEGRITY in FLASH is wrong.
EPAS uC internal memory (EOL param storage) integrity failure at startup.
EPAS full loss of assist.
This alert is reported by the HwResetHandler_TC3x (RSTH) when the startup test of the protected memory areas has failed.
EPAS microcontroller internal memory (reset management storage) failure (CRC) at startup.
EPAS full loss of assist.
This alert is reported by the STMDriver_TC3x (STMD) component when the System timer (STM) plausibility check fails due to an intolerable time difference between the DMA and STM timestamps.
EPAS microcontroller detected out of sync timers (system timer vs DMA) at startup.
EPAS full loss of assist.
This alert is reported by the MCUFlashChecks_TC3x (MCUFC) component when CRC check failed, consistency of non-inited memory sections did not keep during the restart.
EPAS microcontroller internal memory (non-inited) checks failed (CRC) at startup.
EPAS full loss of assist.
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when CRC check failed, consistency of non-inited memory sections did not keep during the restart.
EPAS microcontroller non-initialized data is corrupted after a reset.
EPAS full loss of assist.
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU internal failure (The Safety FlipFlop Monitoring tests not finished in time).
EPAS Safety FlipFlop Monitoring timeout at startup.
EPAS full loss of assist.
This alert is reported by the MCUSafetyStartupChecks_TC3x (MCUSSC) component when there is a MCU internal failure (The Safety FlipFlop Monitoring tests failed for at least one of the MTU or SMU instances).
EPAS microcontroller internal safety monitoring (SafetyFF at MTU,SMU) reported failure at startup.
EPAS full loss of assist.
This alert is reported when there is a ADC failure, MCU failure.
EPAS uC peripheral ADC acquisition failure at runtime.
EPAS reset
APS_eacMonitor message not received
APS_eacMonitor message not received by EPAS
External Angle Controller inhibited