EPASTP_a080_pwmTimerSyncCheck
Description
This alert is reported by the PWMDriverCD_TC3x component when the control cycle and tasking cycle synchronization mismatch.
Condition
EPAS application component PWM monitor detected failure (control cycle and tasking cycle synchronization mismatch).
Clear Condition
EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.
Potential Impact
EPAS reset. If reset more than 5 times then EPAS full loss of assist.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Model Y;Model Y 2025+