Alerts

Alerts

Signal Name Description Condition Impact Important
A condition affecting right lateral airwave cabin HVAC actuator functionality has been detected.
A condition affecting right lateral airwave actuator is detected.
Right lateral airwave is unable to move left and right.
No
A fault has been detected with the right interior trunk light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The right interior trunk light may not be working.
No
The rear right seat buckle sensor is faulted
Buckle sensor is out of spec
Cannot determine buckle of the seat
No
The rear right seat occupancy sensor is faulted
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
No
The front seat buckle sensor is faulted
Buckle sensor is out of spec
Cannot determine buckle of the seat
No
The rear center seat buckle sensor is faulted
Buckle sensor is out of spec
Cannot determine buckle of the seat
No
The window motors are disabled. The Right Vehicle Controller (VCRIGHT) Electronic Control Unit (ECU) detects an eFuse overcurrent event on the window bridge power feed.
VCRIGHT detects an eFuse overcurrent event (or a trip) on the window bridges power feed. Voltage is above 8V for 200ms on at least one of the right window motor outputs while no outputs are being driven.
Window control is disabled. Right window motor may not operate as expected.
No
The rear right seat occupancy sensor is faulted
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
No
The cabin temperature is below the minimum pump temperature
The measured cabin temperature is below the minimum pump temperature
The pump will be disabled
No
The front seat heater is not heating as expected.
The seat heater duty cycle was set at 100% for 30 minutes.
Front seat heater will be unavailable.
No
The rear right seat occupancy sensor is faulted
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
No
A condition affecting right vertical airwave cabin HVAC actuator functionality has been detected.
A condition affecting right vertical airwave actuator is detected.
Right vertical airwave is unable to move up and down.
No
A side-view mirror started a fold or unfold movement, but then stalled before finishing the movement. The mirror will attempt 1 retry to complete the movement.
Sets if the mirror folding motor current exceeds 0.5A at some point, but then decreases to below 0.1A between 200ms - 1750ms after the beginning of actuation. Also sets at the end of the retry actuation to capture/log additional data.
The mirror will stop for 400ms before attempting the retry. If the mirror unexpectedly stalls again during the retry, it may be left partially folded/unfolded.
No
The brushless HVAC blower motor has experienced a condition affecting functionality. The HVAC blower will not function, and the blower motor driver in the right vehicle controller (VCRIGHT) will be reset to attempt to clear the condition. Note: The reset may only temporarily clear the condition, depending on the cause. For example, the condition will quickly return if the cause is a broken wire or loose connection.
Any of the alert log signals is set (=1), indicating VCRIGHT detects a condition affecting blower motor functionality.
The HVAC blower will not function. The VCRIGHT blower motor driver will be reset to attempt to clear the condition affecting functionality.
No
Glovebox current exceeded expected maximum current, likely indicating that the glovebox connection is short-circuited
Glovebox current draw exceeded maximum current limit
Glovebox disabled or not operational
No
Front handle is stuck unseated, vehicle will not sleep
The handle has been unseated for at least 5 minutes
Vehicle will not sleep due to handle(s) being active
No
Glovebox current did not exceed expected mininum current requirement, likely indicating that the glovebox is not plugged in
Glovebox current draw failed to exceed minimum current requirement
Glovebox disabled or not operational
No
The high side driver (HSD) for the front seat heater has detected an error condition, which may lead to the seat heater not performing as designed.
The high side driver (HSD) for the front seat heater detects an error condition (overcurrent, short to ground, or thermal shutdown).
The front seat heater may not perform as designed.
No
A fault has been detected with the left exterior trunk light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The left exterior trunk light may not be working.
No
The latch did not disarm during a successful release actuation.
The latch home switch remained active during a successful release actuation.
The latch home switch may be incorrectly reporting its state.
No