Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
A condition affecting right lateral airwave cabin HVAC actuator functionality has been detected.
|
A condition affecting right lateral airwave actuator is detected.
|
Right lateral airwave is unable to move left and right.
|
No
|
|
|
A fault has been detected with the right interior trunk light.
|
The light is unplugged, doesn't draw current when on, or its efuse is tripped
|
The right interior trunk light may not be working.
|
No
|
|
|
The rear right seat buckle sensor is faulted
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
No
|
|
|
The rear right seat occupancy sensor is faulted
|
Occupancy sensor is out of spec
|
Cannot determine occupancy of the seat
|
No
|
|
|
The front seat buckle sensor is faulted
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
No
|
|
|
The rear center seat buckle sensor is faulted
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
No
|
|
|
The window motors are disabled. The Right Vehicle Controller (VCRIGHT) Electronic Control Unit (ECU) detects an eFuse overcurrent event on the window bridge power feed.
|
VCRIGHT detects an eFuse overcurrent event (or a trip) on the window bridges power feed. Voltage is above 8V for 200ms on at least one of the right window motor outputs while no outputs are being driven.
|
Window control is disabled. Right window motor may not operate as expected.
|
No
|
|
|
The rear right seat occupancy sensor is faulted
|
Occupancy sensor is out of spec
|
Cannot determine occupancy of the seat
|
No
|
|
|
The cabin temperature is below the minimum pump temperature
|
The measured cabin temperature is below the minimum pump temperature
|
The pump will be disabled
|
No
|
|
|
The front seat heater is not heating as expected.
|
The seat heater duty cycle was set at 100% for 30 minutes.
|
Front seat heater will be unavailable.
|
No
|
|
|
The rear right seat occupancy sensor is faulted
|
Occupancy sensor is out of spec
|
Cannot determine occupancy of the seat
|
No
|
|
|
A condition affecting right vertical airwave cabin HVAC actuator functionality has been detected.
|
A condition affecting right vertical airwave actuator is detected.
|
Right vertical airwave is unable to move up and down.
|
No
|
|
|
A side-view mirror started a fold or unfold movement, but then stalled before finishing the movement. The mirror will attempt 1 retry to complete the movement.
|
Sets if the mirror folding motor current exceeds 0.5A at some point, but then decreases to below 0.1A between 200ms - 1750ms after the beginning of actuation. Also sets at the end of the retry actuation to capture/log additional data.
|
The mirror will stop for 400ms before attempting the retry. If the mirror unexpectedly stalls again during the retry, it may be left partially folded/unfolded.
|
No
|
|
|
The brushless HVAC blower motor has experienced a condition affecting functionality. The HVAC blower will not function, and the blower motor driver in the right vehicle controller (VCRIGHT) will be reset to attempt to clear the condition. Note: The reset may only temporarily clear the condition, depending on the cause. For example, the condition will quickly return if the cause is a broken wire or loose connection.
|
Any of the alert log signals is set (=1), indicating VCRIGHT detects a condition affecting blower motor functionality.
|
The HVAC blower will not function. The VCRIGHT blower motor driver will be reset to attempt to clear the condition affecting functionality.
|
No
|
|
|
Glovebox current exceeded expected maximum current, likely indicating that the glovebox connection is short-circuited
|
Glovebox current draw exceeded maximum current limit
|
Glovebox disabled or not operational
|
No
|
|
|
Front handle is stuck unseated, vehicle will not sleep
|
The handle has been unseated for at least 5 minutes
|
Vehicle will not sleep due to handle(s) being active
|
No
|
|
|
Glovebox current did not exceed expected mininum current requirement, likely indicating that the glovebox is not plugged in
|
Glovebox current draw failed to exceed minimum current requirement
|
Glovebox disabled or not operational
|
No
|
|
|
The high side driver (HSD) for the front seat heater has detected an error condition, which may lead to the seat heater not performing as designed.
|
The high side driver (HSD) for the front seat heater detects an error condition (overcurrent, short to ground, or thermal shutdown).
|
The front seat heater may not perform as designed.
|
No
|
|
|
A fault has been detected with the left exterior trunk light.
|
The light is unplugged, doesn't draw current when on, or its efuse is tripped
|
The left exterior trunk light may not be working.
|
No
|
|
|
The latch did not disarm during a successful release actuation.
|
The latch home switch remained active during a successful release actuation.
|
The latch home switch may be incorrectly reporting its state.
|
No
|