VCRIGHT_a303_eFuseMgmtWindowLift
Description
The window motors are disabled. The Right Vehicle Controller (VCRIGHT) Electronic Control Unit (ECU) detects an eFuse overcurrent event on the window bridge power feed.
Condition
VCRIGHT detects an eFuse overcurrent event (or a trip) on the window bridges power feed. Voltage is above 8V for 200ms on at least one of the right window motor outputs while no outputs are being driven.
Clear Condition
Alert clears automatically after 10 seconds. If alert asserts for a maximum of three times, loads will be disabled. VCRIGHT may require a reset.
Potential Impact
Window control is disabled. Right window motor may not operate as expected.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+