Alerts

Alerts

Signal Name Description Condition Impact
THS is reporting SNA for at least one of its sensor values.
One or more sensors on the THS is reporting a fault
HVAC system will not work nominally
A fault has been detected with the rear right turn indicator.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The rear right turn indicator may not be working. Working turn indicators on that side will blink at double the speed.
The latch did not disarm during a successful release actuation.
The latch home switch remained active during a successful release actuation.
The latch home switch may be incorrectly reporting its state.
The seat lift motor encoder has unexpectedly stalled.
Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.
The seat lift motor encoder may increment incorrectly if an obstruction is encountered.
The seat lift motor has unexpectedly stalled.
Current draw exceeds stall limit.
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
The seat track motor encoder has unexpectedly stalled.
Current draw exceeded 70% of the stall limit, and the encoder did not move for 100ms.
The seat track motor encoder may increment incorrectly if an obstruction is encountered.
The latch did not disarm during a successful release actuation.
The latch home switch remained active during a successful release actuation.
The latch home switch may be incorrectly reporting its state.
The seat tilt motor encoder has unexpectedly stalled.
Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.
The seat tilt motor encoder may increment incorrectly if an obstruction is encountered.
The right vehicle controller (VCRIGHT) detects the HVAC right floor duct actuator is unable to reach the target position within the expected time frame, which may affect the cabin climate control system functionality.
The HVAC right floor duct actuator does not reach the target position within the expected time frame.
Cabin climate control system air conditioning and heating may be limited or unavailable.
Window glass did not drop while opening the door
Was unable to roll down the window when opeing the door
May cause bright damage and difficulty closing the door
One or more of the messages the vehicle controller receives periodically from the usb vehicle controller (VCUSB) is not received, indicating the VCUSB may be unavailable (MIA)
The vehicle controller does not receive one or more of the expected messages from the VCUSB within the expected time frame.
Rear airwaves and USB ports will not be functioning
The latch unexpectedly re-armed while releasing.
The latch home switch returned to active state after going inactive during release.
The latch home switch may be incorrectly reporting its state, or the latch may be over extending.
A fault has been detected with the right map pocket light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The right map pocket light may not be working.
The latch unexpectedly re-armed while releasing.
The latch home switch returned to active state after going inactive while releasing.
The latch home switch may be incorrectly reporting its state, or the latch may be over extending.
PTC heater is faulted due to the reason set in the alert context data
One of the faults on the PTC heater is active
This may result in reduced HVAC heating performance
THS ecu is not responding over LIN
THS is not reporting on LIN
HVAC auto functionality will be compromised
Defrost duct temperature sensor has an electrical fault
The sensor is disconnected or short-circuited to ground
HVAC performance may be limited
HVAC PTC heater is drawing current when not requested
PTC heater is consuming current when it was not commanded
May result in reduced HVAC heating performance
PTC heater stuck in bootloader due to high current at startup
PTC is sending out boot ID when not intended, indicating that it is stuck in bootloader
May result in reduced HVAC heating performance
Second Row Floor duct temperature sensor has an electrical fault
The sensor is disconnected or short-circuited to ground
HVAC performance may be limited