Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
Window glass did not drop while opening the door.
|
Was unable to roll down the window when opeing the door
|
May cause bright damage and difficulty closing the door
|
|
A fault has been detected with the right brake light.
|
The light is unplugged, doesn't draw current when on, or its efuse is tripped
|
The right brake light may not be working.
|
|
A fault has been detected with the right interior trunk light.
|
The light is unplugged, doesn't draw current when on, or its efuse is tripped
|
The right interior trunk light may not be working.
|
|
A condition affecting right lateral airwave cabin HVAC actuator functionality has been detected.
|
A condition affecting right lateral airwave actuator is detected.
|
Right lateral airwave is unable to move left and right.
|
|
The left lower duct temperature sensor has an electrical fault.
|
The sensor is disconnected or short-circuited to ground
|
Cabin climate control system performance may be limited
|
|
One or more of the messages the vehicle controller receives periodically from the usb vehicle controller (VCUSB) is not received, indicating the VCUSB may be unavailable (MIA).
|
The vehicle controller does not receive one or more of the expected messages from the VCUSB within the expected time frame.
|
Rear airwaves and USB ports will not be functioning
|
|
HVAC left floor duct actuator faulted.
|
Left floor duct actuator detected a fault (check context data for type of fault)
|
The heater and the A/C and heater may be disabled
|
|
Rear exterior handle reported disconnected.
|
Handle has just become reconnected or has been disconnected for longer than 1 second
|
If this alert persists the exterior handle may not work
|
|
Mirror stalled unexpectedly while folding or unfolding.
|
If folding motor current exceeds 0.5A or decreases below 0.1A after 500ms from beginning of actuation. Or timeout from current state after 5 seconds.
|
Mirror might be halfway between folded and unfolded
|
|
The window motors are disabled. The Right Vehicle Controller (VCRIGHT) Electronic Control Unit (ECU) detects an eFuse overcurrent event on the window bridge power feed.
|
VCRIGHT detects an eFuse overcurrent event (or a trip) on the window bridges power feed. Voltage is above 8V for 200ms on at least one of the right window motor outputs while no outputs are being driven.
|
Window control is disabled. Right window motor may not operate as expected.
|
|
Front exterior handle reported disconnected.
|
Handle has just become reconnected or has been disconnected for longer than 1 second
|
If this alert persists the exterior handle may not work
|
|
The cabin temperature is below the minimum pump temperature.
|
The measured cabin temperature is below the minimum pump temperature
|
The pump will be disabled
|
|
The rear right seat occupancy sensor is faulted.
|
Occupancy sensor is out of spec
|
Cannot determine occupancy of the seat
|
|
The rear right seat occupancy sensor is faulted.
|
Occupancy sensor is out of spec
|
Cannot determine occupancy of the seat
|
|
The rear right seat occupancy sensor is faulted.
|
Occupancy sensor is out of spec
|
Cannot determine occupancy of the seat
|
|
The cabin temperature is below the minimum pump temperature.
|
The measured cabin temperature is below the minimum pump temperature
|
The pump will be disabled
|
|
The rear right seat buckle sensor is faulted.
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
|
The rear right seat buckle sensor is faulted.
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
|
The rear center seat buckle sensor is faulted.
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
|
The rear right seat buckle sensor is faulted.
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|