Alerts

Alerts

Signal Name Description Condition Impact
Window glass did not drop while opening the door.
Was unable to roll down the window when opeing the door
May cause bright damage and difficulty closing the door
A fault has been detected with the right brake light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The right brake light may not be working.
A fault has been detected with the right interior trunk light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The right interior trunk light may not be working.
A condition affecting right lateral airwave cabin HVAC actuator functionality has been detected.
A condition affecting right lateral airwave actuator is detected.
Right lateral airwave is unable to move left and right.
The left lower duct temperature sensor has an electrical fault.
The sensor is disconnected or short-circuited to ground
Cabin climate control system performance may be limited
One or more of the messages the vehicle controller receives periodically from the usb vehicle controller (VCUSB) is not received, indicating the VCUSB may be unavailable (MIA).
The vehicle controller does not receive one or more of the expected messages from the VCUSB within the expected time frame.
Rear airwaves and USB ports will not be functioning
HVAC left floor duct actuator faulted.
Left floor duct actuator detected a fault (check context data for type of fault)
The heater and the A/C and heater may be disabled
Rear exterior handle reported disconnected.
Handle has just become reconnected or has been disconnected for longer than 1 second
If this alert persists the exterior handle may not work
Mirror stalled unexpectedly while folding or unfolding.
If folding motor current exceeds 0.5A or decreases below 0.1A after 500ms from beginning of actuation. Or timeout from current state after 5 seconds.
Mirror might be halfway between folded and unfolded
The window motors are disabled. The Right Vehicle Controller (VCRIGHT) Electronic Control Unit (ECU) detects an eFuse overcurrent event on the window bridge power feed.
VCRIGHT detects an eFuse overcurrent event (or a trip) on the window bridges power feed. Voltage is above 8V for 200ms on at least one of the right window motor outputs while no outputs are being driven.
Window control is disabled. Right window motor may not operate as expected.
Front exterior handle reported disconnected.
Handle has just become reconnected or has been disconnected for longer than 1 second
If this alert persists the exterior handle may not work
The cabin temperature is below the minimum pump temperature.
The measured cabin temperature is below the minimum pump temperature
The pump will be disabled
The rear right seat occupancy sensor is faulted.
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
The rear right seat occupancy sensor is faulted.
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
The rear right seat occupancy sensor is faulted.
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
The cabin temperature is below the minimum pump temperature.
The measured cabin temperature is below the minimum pump temperature
The pump will be disabled
The rear right seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat
The rear right seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat
The rear center seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat
The rear right seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat