Signal Name Description Condition Impact Important
Window glass did not drop while opening the door
Was unable to roll down the window when opeing the door
May cause bright damage and difficulty closing the door
No
The easy entry pitch unlatch is disabled
The UDS routine to disable easy entry pitch unlatch has been run
The easy entry pitch will not unlatch
No
The brushless HVAC blower motor has experienced a condition affecting functionality. The HVAC blower will not function, and the blower motor driver in the right vehicle controller (VCRIGHT) will be reset to attempt to clear the condition. Note: The reset may only temporarily clear the condition, depending on the cause. For example, the condition will quickly return if the cause is a broken wire or loose connection.
Any of the alert log signals is set (=1), indicating VCRIGHT detects a condition affecting blower motor functionality.
The HVAC blower will not function. The VCRIGHT blower motor driver will be reset to attempt to clear the condition affecting functionality.
No
A condition affecting functionality has been detected with the rear fascia left turn light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The rear fascia left turn light may be partially or fully unlit when the vehicle is braking
No
The front seat buckle sensor is faulted
Buckle sensor is out of spec
Cannot determine buckle of the seat
No
The front seat occupancy sensor is faulted
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
No
Glovebox current exceeded expected maximum current, likely indicating that the glovebox connection is short-circuited
Glovebox current draw exceeded maximum current limit
Glovebox disabled or not operational
No
The high side driver (HSD) for the front seat heater has detected an error condition, which may lead to the seat heater not performing as designed.
The high side driver (HSD) for the front seat heater detects an error condition (overcurrent, short to ground, or thermal shutdown).
The front seat heater may not perform as designed.
No
Front handle is stuck unseated, vehicle will not sleep
The handle has been unseated for at least 5 minutes
Vehicle will not sleep due to handle(s) being active
No
The latch unexpectedly re-armed while releasing.
The latch home switch returned to active state after going inactive while releasing.
The latch home switch may be incorrectly reporting its state, or the latch may be over extending.
No
The latch did not disarm during a successful release actuation.
The latch home switch remained active during a successful release actuation.
The latch home switch may be incorrectly reporting its state.
No
The latch unexpectedly re-armed while releasing.
The latch home switch returned to active state after going inactive during release.
The latch home switch may be incorrectly reporting its state, or the latch may be over extending.
No
The seat heater has had unusually high current draw.
Seat heater current has reached above a permitted threshold.
Seat heater will stop running. Potential damage to harness and seat.
No
Glovebox current did not exceed expected mininum current requirement, likely indicating that the glovebox is not plugged in
Glovebox current draw failed to exceed minimum current requirement
Glovebox disabled or not operational
No
The front seat heater is not heating as expected.
The seat heater duty cycle was set at 100% for 30 minutes.
Front seat heater will be unavailable.
No
The seat track motor encoder has unexpectedly stalled.
Current draw exceeded 70% of the stall limit, and the encoder did not move for 100ms.
The seat track motor encoder may increment incorrectly if an obstruction is encountered.
No
The seat tilt motor encoder has unexpectedly stalled.
Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.
The seat tilt motor encoder may increment incorrectly if an obstruction is encountered.
No
The seat lift motor has unexpectedly stalled.
Current draw exceeds stall limit.
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
No
The seat lift motor encoder has unexpectedly stalled.
Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.
The seat lift motor encoder may increment incorrectly if an obstruction is encountered.
No
PTC heater is faulted due to the reason set in the alert context data
One of the faults on the PTC heater is active
This may result in reduced HVAC heating performance
No