Alerts

Alerts

Signal Name Description Condition Impact
The vehicle controller detects the supply voltage from 1 or more components is outside of the expected range.
The vehicle controller detects the supply voltage from 1 or more components is < 7.31. Alert log signal data should provide more information on the specific condition(s) detected.
Features depending on the vehicle controller functionality may be unavailable or may not function as expected.
Warns if the processor has experienced a reset due to power loss.
Sudden power loss.
Controller is MIA for some time.
Warns if the processor has experienced a reset due to watchdog reset.
A watchdog (external or internal) was not serviced in time.
Controller is MIA for some time.
The fold flat switch remains activated for a duration extending 20 seconds without interruption, suggesting continued pressing despite initial intentions having presumably already been fulfilled.
The fold flat switch remains activated for a duration extending 20 seconds without interruption.
The features the fold flat switch control may be disabled.
The easy entry switch remains activated for a duration extending 20 seconds without interruption, suggesting continued pressing despite initial intentions having presumably already been fulfilled.
The easy entry switch remains activated for a duration extending 20 seconds without interruption.
The features the easy entry switch control may be disabled.
BCS2L_w126_comfortHoldDown
The comfort switch has been pressed more than 20 seconds without interruption
The features that the comfort switch control may be disabled
The HSD will report a fault for any number of reasons, including: the HSD is overheating or the HSD power input is not stable, etc.
The HSD is self-reporting a fault
Seat heater pads will not be powered
BCS2L_w113_3RSeatHeatOverCurr
-
Log contains stack usage for each task.
Stack usage exceeds 80% for any task.
Stack overflow can occur if there is not enough stack space.
A condition affecting switch functionality has been detected.
A condition is detected affecting switch functionality. Alert log signal data should provide more information on the switch affected and specific condition.
The switch may not function or may not function as expected.
A large voltage drop is detected in the input power to the vehicle controller, indicating the resistance on the input power feed to the vehicle controller is higher than expected.
Estimated resistance on the input power feed to the vehicle controller is higher than expected.
The vehicle controller may be unavailable due to lack of adequate input power, limiting vehicle functionality or making the vehicle inoperable, with at least one other alert specific to that condition present.
Stall detection. Check for obstacle detected, high current readings, or running into pitch ends.
The pitch motor reads an unreasonably high or stall current of greater than absolute value of +/-15 amps for greater than 50 ms
The pitch motor will be disabled
Seat heater may be shorted, or faulted
The current measured through the heater is more than expected
The 2nd row seat heater may be disabled
Check for damamged motor
The latch motor reads an unreasonably low current of less than 0.1 amps for greater than 250 ms
The latch motor will be disabled
Latch motor encountered obstruction or end stop not handled by app
The latch motor reads an unreasonably high or stall current of greater than 3.5 amps for greater than 250 ms
The latch motor will be disabled
Overtemp, overload, current limitation, under voltage
The latch motor is running and the status output pin becomes high
The latch motor will be disabled
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row center seat detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
Encoder counts not changing as expected
The pitch motor senses a failure in detecting movement
The pitch motor will be disabled
Current below expected, free spinning. Seat could have pitched out from its screw
Pitch motor senses low current of less than absolute value of +/- 1 amp for greater than 1 second
Pitch motor could be disconnected and seat would not be able to track
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted