Alerts

Alerts

Signal Name Description Condition Impact
Pitch will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine. AlertLog contains uncalibrated reason.
Pitch position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
Pitch motor will stop moving
Seat occupant was detected outside the comfort zone causing Easy Entry Latch to be unable achieve full forward engagement.
Seat occupant was detected outside the comfort zone causing Easy Entry Latch to be unable achieve full forward engagement while in Drive or Reverse mode.
The safety of individuals utilizing the seats may be compromised due to incorrect configurations.
The left second row seat backrest is unlatched.
The vehicle is not in Park, the backrest is unlatched, the track is latched, and the left or center second row seats are occupied.
The backrest may move unexpectedly because it is unlatched.
The right second row seat backrest is unlatched.
The vehicle is not in Park, the backrest is unlatched, the track is latched, and the right second row seat is occupied.
The backrest may move unexpectedly because it is unlatched.
This message contains separate signals for each watchdog reset source.
A watchdog (external or internal) was not serviced in time.
These are the repercussions of the alert being set
Undervoltage detection by the CPU can set this alert.
Sudden power loss.
These are the repercussions of the alert being set
Not Available
Failure of a software assertion.
These are the repercussions of the alert being set
The SBC CAN transceiver has faulted. Alert will be seen if the trasnceiver has recovered from the faulted condition.
The BDY CAN bus communication is not available.
Other ECUs may report this ECU as being MIA and behaviour will be impacted. This alert won't be seen until CAN communcation has returned.
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
Response timeout of a LIN node
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Bridge faults are most likely due to configuration error.
An fault was reported by the bridge driver while initializing or controlling the bridge driver or a bridge channel.
Some or all bridge outputs may not opperate due to a bridge fault.
This alert is used to create the template for the raw alert log. Double check before this alert is used for something else.
Set condition
These are the repercussions of the alert being set
Not Available
Reset can be caused by: Clock Error, Flash Error, Software Reset, Checkstop Reset, Debug Reset
Potential issue with hardware or software caused the reset.
This message contains separate signals for Overvoltage and Undervoltage for each rail.
ECU 5V rail detected < 4.5V or > 5.5V, or 3.3V rail < 3.0V or > 3.6V for 100ms.
These are the repercussions of the alert being set
The electronic control unit (ECU) detects that the supply voltages from 1 or more components are out of range.
The ECU detects the supply voltage is < 7.31V. Specific reason(s) should be available in alert log signal data.
The ECU may be unavailable.
The third row right seat heater is not heating as expected.
The seat heater duty cycle was set at 100% for 30 minutes.
Third row right seat heater will be unavailable.
An issue is indicated from the non-volatile memory manager.
Non-volatile memory misconfiguration or underlying flash/filesystem error.
Non-volatile memory records may be incorrect or missing.