Alerts

Alerts

Signal Name Description Condition Impact Important
The log data contains failure count and up to five init failure codes.
A task init function returns with an error.
If an init routine fails, software may not opperate correctly.
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
Any of the signals in message RCM are set.
These are the repercussions of the alert being set
No
Encoder counts not changing as expected
The pitch motor senses a failure in detecting movement
The pitch motor will be disabled
No
Current below expected, free spinning. Seat could have pitched out from its screw
Pitch motor senses low current of less than absolute value of +/- 1 amp for greater than 1 second
Pitch motor could be disconnected and seat would not be able to track
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
Encoder counts not changing
The track motor senses a failure in detecting movement
The track motor will be disabled
No
3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels
Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V
If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.
No
3930 Fault - short to GND, short to Supply, shorted motor winding
Track motor detects a short
Comfort track and easy entry will be disabled
No
Check if 5V_SW is enabled at startup; check that the seatID pins are being set low in correspondance with the desired side; run UDS routine 204 on the bootloader to read and store the seat config
The ECU did not read the seat ID pins properly on reset
The ECU may not respond to the desired signals
No
3930 Fault - Low Load Current. Senses less than 500mV
Track motor senses low current
Fault flag thrown, track motor will continue to work
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row center seat detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
Seat temperature sensor may be disconnected, shorted, or faulted
The temperature sensor senses a fault and is either shorted or disconnected
The 2nd row seat heater may be disabled
No
Seat heater may be shorted, or faulted
The current measured through the heater is more than expected
The 2nd row seat heater may be disabled
No