Alerts

Alerts

Signal Name Description Condition Impact Important
Check seat temperature sensor for fault
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
The 2nd row seat heater may be disabled
No
Check seat temperature sensor for fault
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
The 2nd row seat heater may be disabled
No
Overtemp, overload, current limitation, under voltage
The latch motor is running and the status output pin becomes high
The latch motor will be disabled
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
No
3930 Fault - short to GND, short to Supply, shorted motor winding
Track motor detects a short
Comfort track and easy entry will be disabled
No
Reconnect track sensor
The track sensor senses a disconnect
Seat calibration will not work
No
Latch motor encountered obstruction or end stop not handled by app
The latch motor reads an unreasonably high or stall current of greater than 3.5 amps for greater than 250 ms
The latch motor will be disabled
No
Check for damamged motor
The latch motor reads an unreasonably low current of less than 0.1 amps for greater than 250 ms
The latch motor will be disabled
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row center seat detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
Current below expected, free spinning. Seat could have pitched out from its screw
Pitch motor senses low current of less than absolute value of +/- 1 amp for greater than 1 second
Pitch motor could be disconnected and seat would not be able to track
No
Encoder counts not changing as expected
The pitch motor senses a failure in detecting movement
The pitch motor will be disabled
No
Check seat temperature sensor for fault
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
The 2nd row seat heater may be disabled
No
reseting the controller should fix the issue
Driver side config stored in NVRAM does not match the config sent by GTW
controller may have behaviors that correspond with the wrong side of the car
No
Encoder counts not changing as expected
The pitch motor senses a failure in detecting movement
The pitch motor will be disabled
No
Current below expected, free spinning. Seat could have pitched out from its screw
Pitch motor senses low current of less than absolute value of +/- 1 amp for greater than 1 second
Pitch motor could be disconnected and seat would not be able to track
No
alert data contains stop reason
Set whenever the seat encounters an unexpected condition and movement stops
Seat movement will be stopped
No
Could potentially have tripped its PTC temp sensor. Track will retry locking in 20 seconds
The track is attempting to actuate, but does not see current feedback
Occupant safety is impacted
No
Check OTP region of DFLASH
Error reading from OTP.
Genealogy information may not be read.
No