Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
3rd row detects occupancy and the seat belt latch is not engaged and the vehicle speed is greater than 16 KPH
|
Occupant safety is impacted
|
|
The left second row seat backrest is unlatched.
|
The vehicle is not in Park, the backrest is unlatched, the track is latched, and the left or center second row seats are occupied.
|
The backrest may move unexpectedly because it is unlatched.
|
|
Check latch cable, damaged microswitch, latch obstruction, latch motor damaged, latch motor harness, damaged ECU.
|
The latch microswitch was not released after 1 second of driving the latch motor to unlatch or did not press after 1 second of driving the latch motor to latch and the pitch encoder count is greater than -10
|
The latch motor will be disabled
|
|
The fold flat switch remains activated for a duration extending 20 seconds without interruption, suggesting continued pressing despite initial intentions having presumably already been fulfilled.
|
The fold flat switch remains activated for a duration extending 20 seconds without interruption.
|
The features the fold flat switch control may be disabled.
|
|
The easy entry switch remains activated for a duration extending 20 seconds without interruption, suggesting continued pressing despite initial intentions having presumably already been fulfilled.
|
The easy entry switch remains activated for a duration extending 20 seconds without interruption.
|
The features the easy entry switch control may be disabled.
|
|
BCS2L_w126_comfortHoldDown
|
The comfort switch has been pressed more than 20 seconds without interruption
|
The features that the comfort switch control may be disabled
|
|
Reconnect track sensor.
|
The track sensor senses a disconnect
|
Seat calibration will not work
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 2nd row center seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 3rd row seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 2nd row seat heater may be disabled
|
|
Seat temperature sensor may be disconnected, shorted, or faulted.
|
The temperature sensor senses a fault and is either shorted or disconnected
|
The 3rd row seat heater may be disabled
|
|
Seat temperature sensor may be disconnected, shorted, or faulted.
|
The temperature sensor senses a fault and is either shorted or disconnected
|
The 2nd row seat heater may be disabled
|
|
The HSD will report a fault for any number of reasons, including: the HSD is overheating or the HSD power input is not stable, etc.
|
The HSD is self-reporting a fault
|
Seat heater pads will not be powered
|
|
BCS2L_w113_3RSeatHeatOverCurr
|
|
-
|
|
Check seat heater pad for damage or disconnected seat heat pad wire.
|
When commanded on, the seat heater temperature has not risen 2 degC or more in the 45 seconds it has been powered on
|
The seat heater may not be operational or may have poor heating performance
|
|
Check seat heater pad for short, check other seat heater alerts as well.
|
Overcurrent, or current measurement error
|
The seat heater is disabled
|
|
Check seat heater pad for damage or disconnected seat heat pad wire.
|
When commanded on, the seat heater temperature has not risen 2 degC or more in the 45 seconds it has been powered on
|
The seat heater may not be operational or may have poor heating performance
|
|
Check seat temperature sensor for fault.
|
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
|
The 2nd row seat heater may be disabled
|
|
Check seat temperature sensor for fault.
|
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
|
The 2nd row seat heater may be disabled
|
|
Log contains stack usage for each task.
|
Stack usage exceeds 80% for any task.
|
Stack overflow can occur if there is not enough stack space.
|