Signal Name | Description | Condition | Impact |
---|---|---|---|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
2nd row center seat detects buckle switch is in the faulted or disconnected voltage range
|
Occupant safety is impacted
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
2nd row detects occupancy and the seat belt latch is not engaged and the vehicle speed is greater than 16 KPH
|
Occupant safety is impacted
|
|
Bridge faults are most likely due to configuration error.
|
An fault was reported by the bridge driver while initializing or controlling the bridge driver or a bridge channel.
|
Some or all bridge outputs may not opperate due to a bridge fault.
|
|
This alert is used to create the template for the raw alert log. Double check before this alert is used for something else.
|
Set condition
|
These are the repercussions of the alert being set
|
|
Not Available
|
Reset can be caused by: Clock Error, Flash Error, Software Reset, Checkstop Reset, Debug Reset
|
Potential issue with hardware or software caused the reset.
|
|
This message contains separate signals for Overvoltage and Undervoltage for each rail.
|
ECU 5V rail detected < 4.5V or > 5.5V, or 3.3V rail < 3.0V or > 3.6V for 100ms.
|
These are the repercussions of the alert being set
|
|
The electronic control unit (ECU) detects that the supply voltages from 1 or more components are out of range.
|
The ECU detects the supply voltage is < 7.31V. Specific reason(s) should be available in alert log signal data.
|
The ECU may be unavailable.
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
Response timeout of a LIN node
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
The SBC CAN transceiver has faulted. Alert will be seen if the trasnceiver has recovered from the faulted condition.
|
The BDY CAN bus communication is not available.
|
Other ECUs may report this ECU as being MIA and behaviour will be impacted. This alert won't be seen until CAN communcation has returned.
|
|
Not Available
|
Failure of a software assertion.
|
These are the repercussions of the alert being set
|
|
Undervoltage detection by the CPU can set this alert.
|
Sudden power loss.
|
These are the repercussions of the alert being set
|
|
This message contains separate signals for each watchdog reset source.
|
A watchdog (external or internal) was not serviced in time.
|
These are the repercussions of the alert being set
|
|
Seat install mode is enabled.
|
Seat install mode is enabled via UDS/ODIN
|
The second row seat will have all track restrictions removed and pitch movement locked out
|
|
The right second row seat backrest is unlatched.
|
The vehicle is not in Park, the backrest is unlatched, the track is latched, and the right second row seat is occupied.
|
The backrest may move unexpectedly because it is unlatched.
|