Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
2nd row detects buckle switch is in the faulted or disconnected voltage range
|
Occupant safety is impacted
|
|
Track motor may be disconnected from track.
|
Track motor senses less than FILL_THIS_OUT amps
|
FILL_THIS_OUT
|
|
Encoder counts not changing.
|
The track motor senses a failure in detecting movement
|
The track motor will be disabled
|
|
Check for obstacle detected, high current readings, or running into track ends.
|
The track motor reads an unreasonably high or stall current of FILL_THIS_OUT amps
|
FILL_THIS_OUT
|
|
3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels.
|
Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V
|
If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.
|
|
3930 Fault - Low Load Current. Senses less than 500mV.
|
Track motor senses low current
|
Fault flag thrown, track motor will continue to work
|
|
3930 Fault - short to GND, short to Supply, shorted motor winding.
|
Track motor detects a short
|
Comfort track and easy entry will be disabled
|
|
Check if 5V_SW is enabled at startup; check that the seatID pins are being set low in correspondance with the desired side; run UDS routine 204 on the bootloader to read and store the seat config.
|
The ECU did not read the seat ID pins properly on reset
|
The ECU may not respond to the desired signals
|
|
Not Available
|
NVRAM detected as uninitialized.
|
These are the repercussions of the alert being set
|
|
Not Available
|
Unsuccessful communication with NVRAM.
|
These are the repercussions of the alert being set
|
|
Not Available
|
NVRAM detected as corrupted.
|
These are the repercussions of the alert being set
|
|
The log data contains failure count and up to five init failure codes.
|
A task init function returns with an error.
|
If an init routine fails, software may not opperate correctly.
|
|
Not Available
|
Flash CRC is corrupted.
|
These are the repercussions of the alert being set
|
|
Not Available
|
Any of the signals in message RCM are set.
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
setcondition
|
These are the repercussions of the alert being set
|
|
Not Available
|
Reasons to keep the controller awake have been the same for greater than one hour
|
The bus could not sleep causing significant range loss for the battery pack
|
|
Not Available
|
A signal is received 10% out of timing 3 times in a row.
|
These are the repercussions of the alert being set
|
|
After a record upgrade is successful, resetting the ECU should clear the alert.
|
Record not found, CRC mismatch, Version mismatch, Version upgrade.
|
Indicate the state of non-volatile data in the ECU.
|