Alerts

Alerts

Signal Name Description Condition Impact
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
2nd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
Track motor may be disconnected from track.
Track motor senses less than FILL_THIS_OUT amps
FILL_THIS_OUT
Encoder counts not changing.
The track motor senses a failure in detecting movement
The track motor will be disabled
Check for obstacle detected, high current readings, or running into track ends.
The track motor reads an unreasonably high or stall current of FILL_THIS_OUT amps
FILL_THIS_OUT
3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels.
Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V
If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.
3930 Fault - Low Load Current. Senses less than 500mV.
Track motor senses low current
Fault flag thrown, track motor will continue to work
3930 Fault - short to GND, short to Supply, shorted motor winding.
Track motor detects a short
Comfort track and easy entry will be disabled
Check if 5V_SW is enabled at startup; check that the seatID pins are being set low in correspondance with the desired side; run UDS routine 204 on the bootloader to read and store the seat config.
The ECU did not read the seat ID pins properly on reset
The ECU may not respond to the desired signals
Not Available
NVRAM detected as uninitialized.
These are the repercussions of the alert being set
Not Available
Unsuccessful communication with NVRAM.
These are the repercussions of the alert being set
Not Available
NVRAM detected as corrupted.
These are the repercussions of the alert being set
The log data contains failure count and up to five init failure codes.
A task init function returns with an error.
If an init routine fails, software may not opperate correctly.
Not Available
Flash CRC is corrupted.
These are the repercussions of the alert being set
Not Available
Any of the signals in message RCM are set.
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
Reasons to keep the controller awake have been the same for greater than one hour
The bus could not sleep causing significant range loss for the battery pack
Not Available
A signal is received 10% out of timing 3 times in a row.
These are the repercussions of the alert being set
After a record upgrade is successful, resetting the ECU should clear the alert.
Record not found, CRC mismatch, Version mismatch, Version upgrade.
Indicate the state of non-volatile data in the ECU.