Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
Check for damamged motor.
|
The latch motor reads an unreasonably low current of less than 0.1 amps for greater than 250 ms
|
The latch motor will be disabled
|
|
Latch motor encountered obstruction or end stop not handled by app.
|
The latch motor reads an unreasonably high or stall current of greater than 3.5 amps for greater than 250 ms
|
The latch motor will be disabled
|
|
Log contains CPU load for each task.
|
CPU load exceeds 80%.
|
High CPU load can indicate ineffecient code.
|
|
Overtemp, overload, current limitation, under voltage.
|
The latch motor is running and the status output pin becomes high
|
The latch motor will be disabled
|
|
Overtemp, overload, current limitation, under voltage.
|
The third row fold flat motor is running and the status output pin becomes high
|
The third row fold flat motor will be disabled
|
|
Overtemp, overload, current limitation, under voltage.
|
The latch and third row fold flat motor is running and the status output pin becomes high
|
The latch or third row fold flat motor will be disabled
|
|
Check VNQ7050AJ open load detection. Current below expected, free spinning.
|
Headrest motor senses low current of FILL_THIS_OUT amps
|
Headrest motor could be disconnected and seat would not be able to track
|
|
None
|
The drive rail is on AND backrest is in the comfort zone AND the track is unlatched
|
Occupant safety is impacted
|
|
alert data contains stop reason.
|
Set whenever the seat encounters an unexpected condition and movement stops
|
Seat movement will be stopped
|
|
none
|
Set when the user attempts to move pitch in both directions and the seat does not move in response
|
Seat movement is stopped
|
|
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
|
ECU Debug Jumper is set.
|
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
|
|
Not Available
|
FILL_THIS_OUT
|
FILL_THIS_OUT
|
|
Seat temperature sensor may be disconnected, shorted, or faulted.
|
The temperature sensor senses a fault and is either shorted or disconnected
|
The 2nd row seat heater may be disabled
|
|
BCS2R_w055_2RCSeatHeatOverCurr
|
|
-
|
|
Encoder counts not changing as expected.
|
The pitch motor senses a failure in detecting movement
|
The pitch motor will be disabled
|
|
Current below expected, free spinning. Seat could have pitched out from its screw.
|
Pitch motor senses low current of less than absolute value of +/- 1 amp for greater than 1 second
|
Pitch motor could be disconnected and seat would not be able to track
|
|
Stall detection. Check for obstacle detected, high current readings, or running into pitch ends.
|
The pitch motor reads an unreasonably high or stall current of greater than absolute value of +/-15 amps for greater than 50 ms
|
The pitch motor will be disabled
|
|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
3rd row detects occupancy sensor is in the faulted or disconnected voltage range
|
Occupant safety is impacted
|
|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
3rd row detects buckle switch is in the faulted or disconnected voltage range
|
Occupant safety is impacted
|
|
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU.
|
2nd row detects occupancy sensor is in the faulted or disconnected voltage range
|
Occupant safety is impacted
|