Signal Name | Description | Condition | Impact |
---|---|---|---|
Pilot level invalid.
|
Pilot level transitions to invalid voltage level.
|
Wall connector will not operate while pilot level is invalid.
|
|
Pilot level invalid.
|
Pilot level transitions to invalid voltage level.
|
Wall connector will not operate while pilot level is invalid.
|
|
Wall connector proximity line disconnected or vehicle is not providing proximity voltage.
|
Proximity line in charge cable has no voltage present, but a vehicle is connected.
|
Wall connector will not allow charging while the proximity line is broken because it cannot determine if the cable is latched.
|
|
Microcontroller supply rail is incorrect.
|
Microcontroller supply voltage is outside of valid range.
|
Wall connector will not operate.
|
|
Wall connector is configured as a slave, but no master was detected.
|
Wall connector is configured as a slave, but no master is present on the sharing network.
|
Wall connector will not operate.
|
|
More than 1 wall connector is configured as a master on the sharing network.
|
More than 1 wall connector configured as a master was detected on the sharing network.
|
Wall connector will not operate.
|
|
Contactor detected as closed when it should be open.
|
Wall connector detects voltage on the contactor output when it should be open.
|
Wall connector will not operate and there is a potential hazardous voltage present on the charge handle.
|
|
Wall connector internal voltage reference is out of acceptable range.
|
Internal voltage reference leaves acceptable range.
|
Wall connector will not operate.
|
|
Output voltage, current, and energy monitoring failure.
|
Metering hardware fails to initialize.
|
Wall connector cannot detect welds, over-current, or meter energy. Wall connector will not operate.
|
|
Alternating current (AC) line phase-locked loop (PLL) failed to lock. Check grid frequency and quality.
|
PLL was unable to identify valid grid frequency and phase.
|
Ground fault circuit interrupter (GFCI) cannot function without locked PLL, wall connector will not operate.
|
|
Master and slave units in the sharing network have different nameplate current ratings.
|
Wall connector nameplate current rating differs from the other wall connector in the sharing network.
|
Wall connector will not operate.
|
|
Pilot level invalid.
|
Pilot level transitions to invalid voltage level.
|
Wall connector will not operate while pilot level is invalid.
|
|
Invalid rotary dial selection.
|
Wall connector current limit selection dial is set to an invalid position.
|
Wall connector will not operate.
|
|
Wall connector charge handle temperature sensor shorted, open, or too cold.
|
Charge handle temperature sensor measured as open or short circuit.
|
Wall connector will not operate.
|
|
Wall connector input terminal temperature sensor shorted, open, or too cold.
|
Input terminal temperature sensor measured as open or short circuit.
|
Wall connector will not operate.
|
|
Wall connector printed circuit board assembly (PCBA) temperature sensor shorted, open, or too cold.
|
PCBA temperature sensor measured as open or short circuit.
|
Wall connector will not operate.
|
|
Master unit current limit set too low.
|
Master unit current limit divided by number of units in the sharing network is less than 6 A.
|
Wall connector will not operate.
|
|
More than 3 units configured as slaves were detected on the sharing network.
|
More than 3 units are configured as slaves in the sharing network.
|
Wall connector will not operate.
|
|
More than 1 wall connector is configured as a master on the sharing network.
|
More than 1 wall connector configured as a master was detected on the sharing network.
|
Wall connector will not operate.
|
|
Wall connector is configured as a slave, but no master was detected.
|
Wall connector is configured as a slave, but no master is present on the sharing network.
|
Wall connector will not operate.
|