| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
Wall connector charge handle temperature sensor shorted, open, or too cold.
|
Charge handle temperature sensor measured as open or short circuit.
|
Wall connector will not operate.
|
No
|
|
|
Wall connector input terminal temperature sensor shorted, open, or too cold.
|
Input terminal temperature sensor measured as open or short circuit.
|
Wall connector will not operate.
|
No
|
|
|
Wall connector printed circuit board assembly (PCBA) temperature sensor shorted, open, or too cold.
|
PCBA temperature sensor measured as open or short circuit.
|
Wall connector will not operate.
|
No
|
|
|
Master unit current limit set too low.
|
Master unit current limit divided by number of units in the sharing network is less than 6 A.
|
Wall connector will not operate.
|
No
|
|
|
More than 3 units configured as slaves were detected on the sharing network.
|
More than 3 units are configured as slaves in the sharing network.
|
Wall connector will not operate.
|
No
|
|
|
CHGS_f003_hwBiasBoost
|
|
-
|
No
|
|
|
Wall connector charge handle is too hot.
|
Wall connector handle temperature exceeds 65 degC.
|
Charging rate will be reduced by 50 percent and red LEDs blink once.
|
No
|
|
|
Input wiring terminals are too hot as detected by non-contact infrared (IR) sensor.
|
Input wiring terminal IR emission exceeds threshold.
|
Charging rate will be reduced by 50 percent and red LEDs blink once.
|
No
|
|
|
CHGS_d001_replaceCharger
|
|
-
|
No
|
|
|
CHGS_d002_12VOV
|
|
-
|
No
|
|
|
CHGS_d003_12VUV
|
|
-
|
No
|
|
|
CHGS_d004_overTemp
|
|
-
|
No
|
|
|
CHGS_d005_lowFlow
|
|
-
|
No
|
|
|
CHGS_d006_HVUV
|
|
-
|
No
|
|
|
CHGS_d008_FCWeld
|
|
-
|
No
|
|
|
CHGS_d009_FCWontClose
|
|
-
|
No
|
|
|
CHGS_d010_FCCnctrPower
|
|
-
|
No
|
|
|
CHGS_d011_proxRationality
|
|
-
|
No
|
|
|
CHGS_d012_lostComms
|
|
-
|
No
|
|
|
CHGS_d013_HVIL
|
|
-
|
No
|