Signal Name Description Condition Impact
CHGS_f002_hwBoost
-
CHGS_f001_hwBuck
-
CHGS_d014_15VUV
-
CHGS_d013_HVIL
-
CHGS_d011_proxRationality
-
CHGS_d010_FCCnctrPower
-
CHGS_d009_FCWontClose
-
CHGS_d008_FCWeld
-
CHGS_d006_HVUV
-
CHGS_d005_lowFlow
-
CHGS_d004_overTemp
-
CHGS_d003_12VUV
-
CHGS_d002_12VOV
-
CHGS_d001_replaceCharger
-
Input wiring terminals are too hot as detected by non-contact infrared (IR) sensor.
Input wiring terminal IR emission exceeds threshold.
Charging rate will be reduced by 50 percent and red LEDs blink once.
Wall connector charge handle is too hot.
Wall connector handle temperature exceeds 65 degC.
Charging rate will be reduced by 50 percent and red LEDs blink once.
Wall connector real-time processor is too hot.
Real-time processor exceeds 85 degC.
Charging will be interrupted and red LEDs blink once.
Wall connector Wi-Fi module hasn't checked in with the real-time processor.
Wi-Fi module has failed to check in due to a long running process, update, or software bug.
Charging will continue normally, but connectivity and billing may be delayed or unavailable.
Wall connector internal watchdog timer expired and the unit is about to reboot.
A software bug or upset caused the watchdog timer to expire.
Charging will be momentarily interrupted.
Wall connector contactor output shows no voltage when expected to be closed on one or more phases.
No voltage is seen on wall connector output when contactors are expected to be closed.
Wall connector will not operate.