Signal Name Description Condition Impact
The amplifier reports an overcurrent error on one or more of its channels. This alert can indicate a condition affecting the amplifier hardware.
The amplifier reports one or more of its channels is overcurrent.
One or more of the amplifier channels is not operating as expected. Audio will not operate as expected, and the amplifier may be shorted.
The Ethernet Generalized Gateway (EGGxxx) detects a condition affecting the health of the second amplifier.
An amplifier condition is reported on second amp. Alert log signal data should provide more information on the specific condition(s) detected.
Audio quality may decrease.
The Ethernet Generalized Gateway (EGGxxx) detects a condition affecting the health of the amplifier. .
An amplifier condition is reported. Alert log signal data should provide more information on the specific condition(s) detected.
Audio quality may decrease.
A condition affecting Etherloop communication has been detected, such as a link down, electronic control unit (ECU) / switch down, or power domain issue.
Etherloop Generalized Gateway (EGG) has detected a condition affecting Etherloop communication.
Loss of communication redundancy or total loss of communication between some electronic control units (ECUs).
The signal quality of the Ethernet Generalized Gateway (EGG) clockwise Ethernet link to EGGLEFT is lower than expected and may result in packet loss.
The SQI of the EGG clockwise Ethernet link to EGGLEFT is less than 4.
The Ethernet packet loss affects the vehicle's functionality and performance.
The signal quality of the Ethernet Generalized Gateway (EGG) counterclockwise Ethernet link to EGGRIGHT is lower than expected and may result in packet loss.
The SQI of the EGG counterclockwise Ethernet link to EGGRIGHT is less than 4.
The Ethernet packet loss affects the vehicle's functionality and performance.
The Ethernet Generalized Gateway (EGG) clockwise Ethernet link to EGGLEFT is unavailable. Vehicle communications cannot be transmitted or received on this link.
The EGG clockwise Ethernet link to EGGLEFT is down.
Vehicle communications cannot be transmitted or received on this Ethernet link.
The Ethernet Generalized Gateway (EGG) counterclockwise Ethernet link to EGGRIGHT is unavailable. Vehicle communications cannot be transmitted or received on this link.
The EGG counterclockwise Ethernet link to EGGRIGHT is down.
Vehicle communications cannot be transmitted or received on this Ethernet link.
Etherloop Generalized Gateway (EGGREAR) detects a condition affecting BP CAN bus. Alert log signal data should provide more information on specific condition.
Number of CAN transmit or receive errors exceeds 127.
EGGREAR is unable to transmit or receive messages on BP CAN bus, making communication unavailable.
Etherloop Generalized Gateway (EGGREAR) detects a condition affecting DIPR CAN bus. Alert log signal data should provide more information on specific condition.
Number of CAN transmit or receive errors exceeds 127.
EGGREAR is unable to transmit or receive messages on DIPR CAN bus, making communication unavailable.
Etherloop Generalized Gateway (EGGREAR) detects a condition affecting REARSTEER CAN bus. Alert log signal data should provide more information on specific condition.
Number of CAN transmit or receive errors exceeds 127.
EGGREAR is unable to transmit or receive messages on REARSTEER CAN bus, making communication unavailable.
Etherloop Generalized Gateway (EGGREAR) detects a condition affecting EGGREARPRIV CAN bus. Alert log signal data should provide more information on specific condition.
Number of CAN transmit or receive errors exceeds 127.
EGGREAR is unable to transmit or receive messages on EGGREARPRIV CAN bus, making communication unavailable.
Right Tonneau Motor has drawn more current than expected during calibration, Inspect body fit.
More than 4A was drawn during calibration for 500ms
Tonneau is drawing more current than expected, tonneau features and durability may be affected
Left Tonneau Motor has drawn more current than expected during calibration. Inspect body fit.
More than 4A was drawn during calibration for 500ms
Tonneau is drawing more current than expected, tonneau features and durability may be affected
Right tonneau overuse has been detected, maximum number of events per time exceeded.
The maximum number of operating events per time has been exceeded
The right tonneau motor will be disabled
Left tonneau overuse has been detected, maximum number of events per time exceeded.
The maximum number of operating events per time has been exceeded
The left tonneau motor will be disabled
Right tonneau motor overuse has been detected, with number of events within 5 minutes required to generate a warning exceeded.
The number of operating events per time period required to generate a warning for right tonneau motor overuse has been exceeded
The right tonneau motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded
Left tonneau motor overuse has been detected, with number of events within 5 minutes required to generate a warning exceeded.
The number of operating events per time period required to generate a warning for left tonneau motor overuse has been exceeded
The left tonneau motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded
The tonneau controller has detected that the left tonneau motor has exceeded normal operating times.
The operating time has exceeded 90 seconds within 4.5 minutes
The left tonneau motor will be disabled
The tonneau controller has detected that the right tonneau motor is close to exceeding normal operating times.
The operating time has exceeded 75 seconds within 4.5 minutes
The right tonneau motor will only open and will be disabled if operation is continued and exceeds 90 seconds within 4.5 minutes