Signal Name Description Condition Impact
The backrest motor is uncalibrated
Motor calibrated is 0
Position recall unavailable
The tilt motor is uncalibrated
Motor calibrated is 0
Position recall unavailable
The motor isn't responding
Motor current is 0
seat motor can't move
The motor isn't responding
Motor current is 0
seat motor can't move
The motor isn't responding
Motor current is 0
seat motor can't move
The motor isn't providing encoder feedback
Current draw is nonzero and not stalling but encoder values don't increase
Memory recall will be unavailable
The motor isn't providing encoder feedback
Current draw is nonzero and not stalling but encoder values don't increase
Memory recall will be unavailable
The motor isn't providing encoder feedback
Current draw is nonzero and not stalling but encoder values don't increase
Memory recall will be unavailable
The motor isn't providing encoder feedback
Current draw is nonzero and not stalling but encoder values don't increase
Memory recall will be unavailable
Unexpected voltage seen on non-continuous device outputs
Voltage is above 35V for 10 seconds on at least one of the device outputs while none of them are being driven
Electrical loads for frunk strut and frunk motor control may be unavailable.
The Ethernet Generalized Gateway (EGGxxx) detects a condition affecting the health of the amplifier.
An amplifier condition is reported. Alert log signal data should provide more information on the specific condition(s) detected.
Audio quality may decrease.
The backrest motor encoder has unexpectedly stalled
Current draw exceeds 70% of stall limit and encoder not moving for 100ms
Encoder may increment incorrectly if obstruction encountered
The seat has detected that the track motor has exceeded normal operating times
The operating time has exceeded 120 seconds within 5 minutes
The seat track motor will be disabled
Seat track motor abuse has been detected, with number of events within 5 minutes required to generate a warning exceeded
The number of operating events per time period required to generate a warning for seat track motor abuse has been exceeded
The seat track motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded
While the frunk was requested to open or close, the follower strut issued an unexpected stop request, preventing the frunk from completing the requested movement
The follower strut issued an unexpected stop request
The request to open or close the frunk may not be completed
The motor has traveled beyond the expected range
seat position goes outside the acceptable range
Seat may be in an unstable position or a mechanism may have failed
The motor has traveled beyond the expected range
seat position goes outside the acceptable range
Seat may be in an unstable position or a mechanism may have failed
The seat has detected that the track motor is close to exceeding normal operating times
The operating time has exceeded 90 seconds within 5 minutes
The seat track motor will be disabled if operation is continued and exceeds 120 seconds within 5 minutes
One or more of the expected CAN messages from the Etherloop Generalized Gateway Right (Core 0) were not received, indicating the EGGRIGHT ECU may be unavailable (MIA).
The local ECU does not receive one or more of the expected messages from the EGGRIGHT within the expected time frame.
Vehicle functions that depend on the EGGRIGHT may be unavailable or may not function as expected.
One or more of the messages the vehicle controller receives periodically from the Restraint Control Module (RCM) is not received, indicating the RCM may be unavailable (MIA).
The vehicle controller does not receive one or more of the expected messages from the RCM within the expected time frame.
Vehicle functions that depend on the RCM may be unavailable or may not function as expected.