Signal Name Description Condition Impact
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a internal Protection exception
EPAS application component ExceptionHandler detected exception (internal protection).
EPAS reset
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a SPB bus violation
EPAS application component ExceptionHandler detected exception (SPB bus violation).
EPAS reset
This alert is reported by the OsErrorHandler_R12 (OSEH) component at startup after an immediate reset caused by OS error occurred in ASIL D partition. This diagnostic monitors if the OS had sensed some error in its services.
At startup after an immediate reset caused by OS error occurred in ASIL D partition.
EPAS reset
This alert is reported by the HwResetHandler_TC3x (RSTH) component when there is a MCU internal bus fault.
MCU internal bus fault.
EPAS reset
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a system Bus or Peripheral Error exception other than a floating point exception
EPAS application component ExceptionHandler detected exception (system bus or peripheral error)
EPAS reset
This alert is reported by the HwResetHandler_TC3x (RSTH) component when there is a failure to correct data error in critical MCU registers.
EPAS Failure to correct data error in critical MCU registers.
EPAS reset
This alert is reported by ActuatorManager_R12 (AM) component when there is a phase relay shorted.
EPAS detected a phase relay short failure.
EPAS full loss of assist.
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is NMI caused by other alarms. Memory access violation check. This diagnostic checks if a thread or other bus master (e.g. DMA) tries to access memory region that it is not authorized to access.
EPAS application component ExceptionHandler detected exception (other alarms caused NMI).
EPAS reset
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a SRI bus violation.
EPAS application component ExceptionHandler detected exception (SRI bus violation).
EPAS reset
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is an unexpected interrupt on either core.
EPAS application component ExceptionHandler detected exception (unexpected interrupt).
EPAS reset
This alert is reported by the ExceptionHandler_TC3x (EXHA) component when there is a bus level MPU violation
EPAS application component ExceptionHandler detected exception (bus level MPU violation).
EPAS reset
This alert is reported when the ElapsedTimeSinceReset (ETSR) counter becomes greater than the ETSR_THRESHOLD_TIMESTAMP and counter forced to 0xFFFFFFFF
EPAS elapsed time since reset (ETSR) counter becomes greater than the tolarated limit and counter forced to 0xFFFFFFFF.
EPAS QM reset when is less likely to disturb the driver. If it is not possible, there will be incoming communication freeze and a reset.
This alert is reported when ALM7[31] Flash Stored Configuration Error alarm
EPAS application component ExceptionHandler detected exception (FSI flashed stored config storage).
EPAS reset.
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a phase current shunt temperature higher than limit or not available
EPAS application actuator temperature diagnostics detected overtemperature (phase current shunt).
EPAS full loss of assist.
This alert is reported by the TemperatureDiagnostics_Actuator_R12 (TDA) component when there is a DC Bus shunt temperature higher than limit or not available
EPAS application actuator temperature diagnostics detected overtemperature (DC bus shunt).
EPAS full loss of assist.
This alert is reported by the ExceptionHandler_TC3x (EXCH) component when there is a double bit ECC error in the active pflash and additional ECC errors were found in the same wordline
EPAS application component ExceptionHandler detected unrecoverable memory failure (other page PFlash ECC fault).
EPAS full loss of assist.
This alert is reported when there is a GDU communication failure
EPAS ECU GDU device monitor detected failure (wrong parity bit on serial communication). After consecutives retries and error is still present.
EPAS full loss of assist.
This alert is reported by the StreamingDataStorageManager_R12 (SDSM) component when the CRC is not equal to saved CRC value at any memory block, but another is correct
CRC is not equal to saved CRC value at any memory block, but another is correct.
EPAS fast restart was not possible.
This alert is reported when the wake-up (WKP) or overrun (OVRUN) bits is set in the PMSWSTAT2 register
The wake-up (WKP) or overrun (OVRUN) bits is set in the PMSWSTAT2 register. PMSWSTAT2.ESR0WKP is set after reset.
EPAS reset. If reset more than 3 times then EPAS full loss of assist.
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when wrong ECU_ID in FLASH
EPAS End Of Line ECU ID is incorrect.
EPAS full loss of assist.