Signal Name Description Condition Impact
Rear defrost is drawing more current than expected.
Rear defrost current is above the expected value
None, for engineering logging
A condition affecting right vertical airwave cabin HVAC actuator functionality has been detected.
A condition affecting right vertical airwave actuator is detected.
Right vertical airwave is unable to move up and down.
The rear right seat occupancy sensor is faulted.
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
The rear right seat occupancy sensor is faulted.
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
The rear right seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat
The front seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat
The cabin temperature is below the minimum pump temperature.
The measured cabin temperature is below the minimum pump temperature
The pump will be disabled
The rear center seat buckle sensor is faulted.
Buckle sensor is out of spec
Cannot determine buckle of the seat
A fault has been detected with the right map pocket light.
The light is unplugged, doesn't draw current when on, or its efuse is tripped
The right map pocket light may not be working.
The front seat heater is not heating as expected.
The seat heater duty cycle was set at 100% for 30 minutes.
Front seat heater will be unavailable.
The front seat occupancy sensor is faulted.
Occupancy sensor is out of spec
Cannot determine occupancy of the seat
The current sense for the HVAC PTC heater is saturated to maximum sensable value.
ADC is saturated to maximum value detectable for PTC, THS, Glove Box HSD
Potential short condition on the PTC, THS, or Glove Box LED circuits
The high side driver (HSD) for the front seat heater has detected an error condition, which may lead to the seat heater not performing as designed.
The high side driver (HSD) for the front seat heater detects an error condition (overcurrent, short to ground, or thermal shutdown).
The front seat heater may not perform as designed.
The seat heater has had unusually high current draw.
Seat heater current has reached above a permitted threshold.
Seat heater will stop running. Potential damage to harness and seat.
The dew point sensor (DPS) relative humidity measurement is unavailable.
The DPS relative humidity value is not received via Local Interconnect Network (LIN)
Cabin climate control system performance may be limited
Defrost duct temperature sensor has an electrical fault.
The sensor is disconnected or short-circuited to ground
HVAC performance may be limited
The dew point sensor (DPS) temperature measurement is unavailable.
The DPS temperature is not received via Local Interconnect Network (LIN)
Cabin climate control system performance may be limited
FOHM detects an issue with the input voltage.
FOHM detects VBAT faults
Loss of functionality due to system failure
Second Row Panel duct temperature sensor is SNA on CAN.
The second row panel temperature is not received on CAN
HVAC performance may be limited
handle sleep efuse tripped.
handle sleep voltage is less than 6V
interior handles temporarily unavailable