Signal Name Description Condition Impact Important
Tried to close negative contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Negative FC contactor will remain open.
No
Tried to close positive contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Positive FC contactor will remain open.
No
Did not try to close negative contactor because a voltage match was not achieved.
Contactor state is OPEN and the PULLED_IN state has been blocked for more than 10s because a required HV voltage match has not been achieved.
Negative FC contactor will remain open.
No
Did not try to close positive contactor because a voltage match was not achieved.
Contactor state is OPEN and the PULLED_IN state has been blocked for more than 10s because a required HV voltage match has not been achieved.
Positive FC contactor will remain open.
No
FC contactor opened unexpectedly due to insufficient contactor drive voltage.
Contactor control state exited CLOSED because of insufficient contactor power voltage.
Vehicle will stop charging.
No
FC contactor exited the economized state unexpectedly. Possibly insufficient coil drive current.
Contactor control state exited CLOSED because either of the contactors exited ECONOMIZED.
Vehicle will stop charging.
No
Tried to close FC contactors but failed because a voltage match was not maintained.
Contactor control state exited CLOSING due to voltage match being lost.
FC contactors will remain open.
No
FC contactors were blocked from opening due to high current. Pyro deployed instead.
Charge current is above threshold while trying to open FC contactors.
The positive and negative pyro fuses will be deployed.
No
Pyro fuse deployment was triggered by firmware but did not successfully execute.
Pyro fuse deployment was recently triggered and the deployment failed.
Pyro deployment may be compromised.
No
Pyro fuse deployment was triggered by firmware.
Pyro fuse deployment was triggered by firmware.
Fast Charge (FC) link is offline and DC link is split.
No
Pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
Pyro fuse deployment test failed
Pyro deployment may be compromised
No
A crash event has occurred resulting in the potential deployment one or more High Voltage (HV) system pyro fuses.
The Restraint Control Module (RCM) reports a crash via 1kHz Emergency Notification Signal (ENS) tones.
All subpack pyro fuses will be deployed. Fast Charge (FC) pyro fuses may be deployed, and the vehicle may not drive or charge.
No
The HvSense measurement Application-specific Integrated Circuit (ASIC) has a Serial Peripheral Interface (SPI) communication fault or other internal fault.
Fault condition was set during SPI communications.
HvSense readings are stale.
No
The HvSense measurement Application-specific Integrated Circuit (ASIC) is not producing or communicating data.
A timeout has occurred on the expected communication from the ASIC.
HvSense readings are stale.
No
HV Up is blocked by HVLINK because HVIL is not good.
HVIL is not good and BMS requests that the DC Link be energized
DC Link may fail to energize
No
The High Voltage Battery Subpack 2 (HVPACK2) is not reporting to the High Voltage DC Link Controller (HVLINK) on the Controller Area Network (CAN).
HVPACK2_interlocks is not received by HVLINK within the MIA qualification time interval.
HVLINK shall assume HVPACK2_pyroTestResponse = 0.
No
The High Voltage Battery Subpack 1 (HVPACK1) is not reporting to the High Voltage DC Link Controller (HVLINK) on the Controller Area Network (CAN).
HVPACK1_interlocks is not received by HVLINK within the MIA qualification time interval.
HVLINK shall assume HVPACK1_pyroTestResponse = 0.
No
A crash event has occurred resulting in the potential deployment one or more High Voltage (HV) system pyro fuses.
The Restraint Control Module (RCM) reports a crash over CAN while Emergency Notification Signal (ENS) tones are absent.
All subpack pyro fuses will be deployed. Fast Charge (FC) pyro fuses may be deployed, and the vehicle may not drive or charge.
No
The DCLink bus is shorted, preventing the ability to precharge contactors.
The energy consumed by the precharge Integrated Circuit (IC) during a precharge event exceeds the maximum allowed precharge energy.
Precharging will be halted and the vehicle will be unable to precharge its contactors.
No
Warns if the DCLink bus impedance is too high during precharge.
The precharge Integrated Circuit (IC) sets the prechargeDone hardware line, indicating that the DCLink bus voltage has reached 1100V.
The vehicle will not be able to precharge its contactors.
No