Signal Name | Description | Condition | Impact |
---|---|---|---|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) bed outlet line 1 relay may be welded.
|
The ACJB bed outlet line 1 relay may be welded
|
AC charging unavailable.
|
|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) neutral relay may be welded.
|
The ACJB charge port neutral relay may be welded
|
Outlets unavailable. DC charging unavailable.
|
|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) line relay may be welded.
|
The ACJB charge port line relay may be welded
|
Outlets unavailable. DC charging unavailable.
|
|
High Voltage Battery (HVBATT) electronic control unit (ECU) detects loss of low voltage (LV) input power.
|
HVBATT detects its LV input power is lower than the minimum required input voltage.
|
Vehicle may not drive or charge.
|
|
The bed NEMA 520 outlet current sensor voltage reference rail is not within the nominal operating range.
|
The voltage reference rail for the bed NEMA 520 outlet current sensor is not within the nominal operating range.
|
AC outlets may be unavailable.
|
|
The cabin outlet current sensor voltage reference rail is not within the nominal operating range.
|
The voltage reference rail for the cabin outlet current sensor is not within the nominal operating range.
|
AC outlets may be unavailable.
|
|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) bed outlet line 3 relay has welded.
|
A welded ACJB bed outlet line 3 relay is detected
|
AC charging unavailable.
|
|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) bed outlet line 1 relay has welded.
|
A welded ACJB bed outlet line 1 relay is detected
|
AC charging unavailable.
|
|
There was an implausible brick voltage change.
|
A brick voltage deviated by an implausible amount in-between sensor samples.
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
The maximum charge level of the battery is limited by one or more alerts.
|
One or more battery management system (BMS) alerts that reduce the maximum charge limit are set.
|
Maximum charge is reduced.
|
|
The maximum charge level of the high voltage (HV) battery is exceeded.
|
One or more battery management system (BMS) alerts that reduce the maximum charge limit are set, and the instantaneous charge level is higher than that limit.
|
Vehicle will not be able to charge if connected to a power source, as the reduced maximum HV battery charge level is exceeded.
|
|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) neutral relay has welded.
|
A welded ACJB charge port neutral relay is detected
|
Outlets unavailable. DC charging unavailable.
|
|
The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) line relay has welded.
|
A welded ACJB charge port line relay is detected
|
Outlets unavailable. DC charging unavailable.
|
|
The configured battery pack 2 passive pyro setpoint is invalid.
|
The configured battery pack 2 passive pyro setpoint is invalid
|
Vehicle performance may be reduced
|
|
The configured battery pack 1 passive pyro setpoint is invalid.
|
The configured battery pack 1 passive pyro setpoint is invalid
|
Vehicle performance may be reduced
|
|
The High Voltage Battery (HVBATT) detects the standby supply is stuck in the OFF state.
|
The standby supply voltage has been under the defined threshold for the defined timeout.
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
The High Voltage Battery (HVBATT) detects the standby supply is stuck in the on state.
|
The standby supply voltage has been above the defined threshold for more than the defined timeout.
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
The standby supply is unable to activate because no eligible power sources are available.
|
The standby supply output is requested but there are no subpacks available for use.
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
HVBATT detects that the sum of brick voltages deviates from measured pack voltage.
|
HVBATT detects that the sum of brick voltages in BP2 deviates from pack voltage by more than 5 percent.
|
Inability to charge, drive, or support the low voltage (LV) system
|
|
HVBATT detects that the sum of brick voltages deviates from measured pack voltage.
|
HVBATT detects that the sum of brick voltages in BP1 deviates from pack voltage by more than 5 percent.
|
Inability to charge, drive, or support the low voltage (LV) system
|