Alerts

Alerts

Signal Name Description Condition Impact
Incorrect, missing, or unsupported board part number programmed.
HVPACK detects an unexpected board part number
HVPACK is unable to initialize parameters related to printed circuit board assembly (PCBA) configuration
Incorrect or Missing configuration block programmed.
HVPACK config block may be missing, incorrect, or unsupported
HVPACK is unable to initialize configuration parameters
High Voltage Battery Pack (HVPACK) reports the shunt bar temperature is lower than expected.
Shunt bar temperature is outside the expected threshold.
This alert is primarily informational and is used for logging purposes.
Positive contactor opened unexpectedly due to insufficient coil drive current.
Contactor state exited ECONOMIZED because coil current was too low.
Vehicle may lose propulsion or be unable to support LV system.
Tried to close negative contactor but failed because a voltage match was not maintained.
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
Negative pack contactor will remain open.
Tried to close positive contactor but failed because a voltage match was not maintained.
Contactor state timed out of PULLED_IN because a voltage match was not maintained.
Positive pack contactor will remain open.
Tried to close negative contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Negative pack contactor will remain open.
Tried to close positive contactor but failed because the coil drive current was too low.
Contactor state timed out of PULLED_IN because of insufficient contactor coil current.
Positive pack contactor will remain open.
Did not try to close negative contactor because a voltage match was not achieved.
Contactor state is OPEN and the PULLED_IN state has been blocked for more than 10s because a required HV voltage match has not been achieved.
Negative pack contactor will remain open.
Did not try to close positive contactor because a voltage match was not achieved.
Contactor state is OPEN and the PULLED_IN state has been blocked for more than 10s because a required HV voltage match has not been achieved.
Positive pack contactor will remain open.
Contactor opened unexpectedly due to insufficient contactor drive voltage.
Contactor control state exited CLOSED because of insufficient contactor power voltage.
Vehicle may lose propulsion or be unable to support LV system.
Pack contactor exited the economized state unexpectedly. Possibly insufficient coil drive current.
Contactor control state exited CLOSED because either of the contactors exited ECONOMIZED.
Vehicle may lose propulsion or be unable to support LV system.
Tried to close pack contactors but failed because a voltage match was not maintained.
Contactor control state exited CLOSING due to voltage match being lost.
Pack contactors will remain open.
The HvSense measurement asic has a SPI communication fault or other internal fault.
Fault condition was set during SPI communications
HvSense readings are stale
Pack contactors were blocked from opening due to high current. Pyro deployed instead.
Pack current is above threshold while trying to open pack contactors.
The positive and negative pyro fuses will be deployed.
The battery management system (BMS) has encountered an issue while charging or attempting to charge.
The BMS detects a condition that prevents it from starting charging.
Inability to charge, drive, or support the low voltage (LV) system
The High Voltage Battery (HVBATT) detects the Charge Port High Voltage Interlock Loop (CPIL) is open.
The HVBATT has detected that CPIL is open.
The vehicle may be unable to charge.
The HvSense measurement Application-specific Integrated Circuit (ASIC) has a Serial Peripheral Interface (SPI) communication fault or other internal fault.
Fault condition was set during SPI communications.
HvSense readings are stale.
The HvSense measurement Application-specific Integrated Circuit (ASIC) is not producing or communicating data.
A timeout has occurred on the expected communication from the ASIC.
HvSense readings are stale.
HV Up is blocked by HVLINK because HVIL is not good.
HVIL is not good and BMS requests that the DC Link be energized
DC Link may fail to energize