Signal Name | Description | Condition | Impact |
---|---|---|---|
The rear right seat buckle sensor is faulted.
|
Buckle sensor is out of spec
|
Cannot determine buckle of the seat
|
|
A fault has been detected with the right brake light.
|
The light is unplugged, doesn't draw current when on, or its efuse is tripped
|
The right brake light may not be working.
|
|
The dew point sensor (DPS) temperature measurement is unavailable.
|
The DPS temperature is not received via Local Interconnect Network (LIN)
|
Cabin climate control system performance may be limited
|
|
Filtered ambient temperature sensor is SNA on CAN.
|
The filtered ambient temperature is not received on CAN
|
HVAC performance may be limited
|
|
Defrost duct temperature sensor has an electrical fault.
|
The sensor is disconnected or short-circuited to ground
|
HVAC performance may be limited
|
|
handle sleep efuse tripped.
|
handle sleep voltage is less than 6V
|
interior handles temporarily unavailable
|
|
Force sensor calibration is invalid.
|
Force sensor calibration is invalid
|
Loss of functionality due to system failure
|
|
The dew point sensor (DPS) relative humidity measurement is unavailable.
|
The DPS relative humidity value is not received via Local Interconnect Network (LIN)
|
Cabin climate control system performance may be limited
|
|
Second Row Panel duct temperature sensor is SNA on CAN.
|
The second row panel temperature is not received on CAN
|
HVAC performance may be limited
|
|
FOHM detects an issue with the input voltage.
|
FOHM detects VBAT faults
|
Loss of functionality due to system failure
|
|
The seat has detected that the track motor has exceeded normal operating times.
|
The operating time has exceeded 120 seconds within 5 minutes
|
The seat track motor will be disabled
|
|
The seat has detected that the track motor is close to exceeding normal operating times.
|
The operating time has exceeded 90 seconds within 5 minutes
|
The seat track motor will be disabled if operation is continued and exceeds 120 seconds within 5 minutes
|
|
Seat track motor abuse has been detected, with number of events within 5 minutes required to generate a warning exceeded.
|
The number of operating events per time period required to generate a warning for seat track motor abuse has been exceeded
|
The seat track motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded
|
|
Visor power supply is currently faulted.
|
Visor power supply is currently faulted
|
Loss of vanity light functionality
|
|
Force sensor test pattern test failed & sensor raw vaues are out of range.
|
Force sensor test pattern test failed & sensor raw vaues are out of range
|
Loss of functionality due to functional safety checks
|
|
HVAC intake actuator is uncalibrated.
|
Intake actuator is not calibrated
|
Cabin heating, cooling, and defogging may be degraded
|
|
The seat track abuse has been detected, maximum number of events per time exceeded.
|
The maximum number of operating events per time has been exceeded
|
The seat track motor will be disabled
|
|
HVAC center console duct actuator is uncalibrated.
|
Center console duct actuator is not calibrated
|
Cabin heating, cooling, and defogging may be degraded
|
|
A condition has been detected affecting the left tail light.
|
The light is unplugged, does not draw current when on, or its EFuse is tripped.
|
The left tail light may not function as expected.
|
|
Check for valid I2C force sensor communication.
|
FOHM detected invalid I2C force sensor communication
|
Loss of functionality due to functional safety checks
|