Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
iBooster (IBST) detected a failure word in case of write service to Electrically Erasable Programmable Read-Only Memory (EEPROM) was unable to complete in expected time interval.
|
IBST detects a failure word in case of write service to EEPROM was unable to complete in expected time interval.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to Application-Specific Integrated Circuit (ASIC) failed. Condition can occur due to an error frame incorrect address or timeout CSIH error.
|
IBST detects SPI transfer to ASIC has failed.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected Application-Specific Integrated Circuit (ASIC) initialization test failed during the initialization task.
|
IBST detected ASIC initialization test failed during the initialization task.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected an internal non-serviceable condition with the Clock Input (CLKIN) on its Application-Specific Integrated Circuit (ASIC).
|
IBST detects an internal non-serviceable condition with CLKIN on its ASIC.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected a Generic Timer Module (GTM) reference frequency error.
|
IBST detects a GTM reference frequency error.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected a Generic Timer Module (GTM) reference frequency error.
|
IBST detects a GTM reference frequency error.
|
IBST may not operate as expected.
|
|
iBooster (IBST) continuous monitor of enable lines detected a missing (low) enable signal.
|
IBST continuous monitor of enable lines detected a missing (low) enable signal.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected watchdog status of system integrate circuit (IC) deviates from the expected status.
|
IBST detects watchdog status of system IC deviates from expected status.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected control over MRG via EN_HY or MRAUC or both is not functional.
|
IBST detects control over MRG via EN_HY or MRAUC or both is notn functional.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected the hydraulic enable line is unable to switch off via the uC and via the system Integrated Circuit (IC).
|
IBST hydraulic enable is unable to switch off via the uC port and system IC.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected the hydraulic enable line is unable to switch via the uC and via the system Integrated Circuit (IC).
|
IBST detects the hydralic enable line is unable to switch via the uC and IC.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected during failsafe logic test that actual and expected watchdog (WD) statuses of system Integrated Circuit (IC) differ.
|
IBST detects actual and expected WD statuses of IC differ during failsafe logic test.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected electric enable in unable to be switched off via the uC port and system Integrated Circuit (IC).
|
IBST electric enable is unable to switch off via the uC port and system IC.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected electric enable in unable to be switched off via the uC port and system Integrated Circuit (IC).
|
IBST electric enable is unable to switch off via the uC port and system IC.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected a failure in system Application-Specific Integrated Circuit (ASIC). Failure is due to an errorpin event not counted.
|
IBST detects an uncounted errorpin event in the system ASIC.
|
IBST may not operate as expected.
|
|
iBooster (IBST) Built-In Self-Test (BIST) did not electrically switch off after too many received and incorrect BIST commands.
|
IBST detects BIST did not electricallt switch off after too many incorrect BIST commands.
|
IBST may not operate as expected.
|
|
iBooster (IBST) detected a missing Built-In Self-Test (BIST) trigger did not electrically switch off as expected.
|
IBST detects BIST trigger did not switch off as expected.
|
IBST may not operate as expected.
|
|
The Range Extender (TREX) bus is in the BusOff state.
|
TREX bus is experiencing a condition affecting its functionality, causing it to enter the BusOff state.
|
The TREX bus is unable to communicate with other components.
|
|
iBooster (IBST) detected the Application-Specific Integrated Circuit (ASIC) current reference is out of range.
|
IBST detects the ASIC current reference is out of range.
|
IBST may not operate as expected.
|
|
iBooster (IBST) monitoring of voltage pre-charge (VPRE) U5V over and undervoltage bits has detected an out of range value.
|
IBST monitoring of VPRE U5V over and undervoltage bits detects an out of range value.
|
IBST may not operate as expected.
|