Alerts

Alerts

Signal Name Description Condition Impact
iBooster (IBST) detected a failure word in case of write service to Electrically Erasable Programmable Read-Only Memory (EEPROM) was unable to complete in expected time interval.
IBST detects a failure word in case of write service to EEPROM was unable to complete in expected time interval.
IBST may not operate as expected.
iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to Application-Specific Integrated Circuit (ASIC) failed. Condition can occur due to an error frame incorrect address or timeout CSIH error.
IBST detects SPI transfer to ASIC has failed.
IBST may not operate as expected.
iBooster (IBST) detected Application-Specific Integrated Circuit (ASIC) initialization test failed during the initialization task.
IBST detected ASIC initialization test failed during the initialization task.
IBST may not operate as expected.
iBooster (IBST) detected an internal non-serviceable condition with the Clock Input (CLKIN) on its Application-Specific Integrated Circuit (ASIC).
IBST detects an internal non-serviceable condition with CLKIN on its ASIC.
IBST may not operate as expected.
iBooster (IBST) detected a Generic Timer Module (GTM) reference frequency error.
IBST detects a GTM reference frequency error.
IBST may not operate as expected.
iBooster (IBST) detected a Generic Timer Module (GTM) reference frequency error.
IBST detects a GTM reference frequency error.
IBST may not operate as expected.
iBooster (IBST) continuous monitor of enable lines detected a missing (low) enable signal.
IBST continuous monitor of enable lines detected a missing (low) enable signal.
IBST may not operate as expected.
iBooster (IBST) detected watchdog status of system integrate circuit (IC) deviates from the expected status.
IBST detects watchdog status of system IC deviates from expected status.
IBST may not operate as expected.
iBooster (IBST) detected control over MRG via EN_HY or MRAUC or both is not functional.
IBST detects control over MRG via EN_HY or MRAUC or both is notn functional.
IBST may not operate as expected.
iBooster (IBST) detected the hydraulic enable line is unable to switch off via the uC and via the system Integrated Circuit (IC).
IBST hydraulic enable is unable to switch off via the uC port and system IC.
IBST may not operate as expected.
iBooster (IBST) detected the hydraulic enable line is unable to switch via the uC and via the system Integrated Circuit (IC).
IBST detects the hydralic enable line is unable to switch via the uC and IC.
IBST may not operate as expected.
iBooster (IBST) detected during failsafe logic test that actual and expected watchdog (WD) statuses of system Integrated Circuit (IC) differ.
IBST detects actual and expected WD statuses of IC differ during failsafe logic test.
IBST may not operate as expected.
iBooster (IBST) detected electric enable in unable to be switched off via the uC port and system Integrated Circuit (IC).
IBST electric enable is unable to switch off via the uC port and system IC.
IBST may not operate as expected.
iBooster (IBST) detected electric enable in unable to be switched off via the uC port and system Integrated Circuit (IC).
IBST electric enable is unable to switch off via the uC port and system IC.
IBST may not operate as expected.
iBooster (IBST) detected a failure in system Application-Specific Integrated Circuit (ASIC). Failure is due to an errorpin event not counted.
IBST detects an uncounted errorpin event in the system ASIC.
IBST may not operate as expected.
iBooster (IBST) Built-In Self-Test (BIST) did not electrically switch off after too many received and incorrect BIST commands.
IBST detects BIST did not electricallt switch off after too many incorrect BIST commands.
IBST may not operate as expected.
iBooster (IBST) detected a missing Built-In Self-Test (BIST) trigger did not electrically switch off as expected.
IBST detects BIST trigger did not switch off as expected.
IBST may not operate as expected.
The Range Extender (TREX) bus is in the BusOff state.
TREX bus is experiencing a condition affecting its functionality, causing it to enter the BusOff state.
The TREX bus is unable to communicate with other components.
iBooster (IBST) detected the Application-Specific Integrated Circuit (ASIC) current reference is out of range.
IBST detects the ASIC current reference is out of range.
IBST may not operate as expected.
iBooster (IBST) monitoring of voltage pre-charge (VPRE) U5V over and undervoltage bits has detected an out of range value.
IBST monitoring of VPRE U5V over and undervoltage bits detects an out of range value.
IBST may not operate as expected.