Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
iBooster (IBST) firmware set in case of temperature degradation level 1.
|
IBST firmware set in case of temperature degradation level 1.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) wear offset value not able to read from Non-volatile Memory (NVM).
|
IBST wear offset value not able to read from NVM.
|
IBST may not operate as expected.
|
No
|
|
|
Indicates IBST pRunout brake pressure was not reached due to motor torque output saturation.
|
Set when IBST cannot reach pRunout with full motor torque output. 300ms debounce time.
|
iBooster will have smaller EBR bandwidth but EBR will be executed by ESP thus no change in overall EBR bandwidth. If motor torque is saturated below legal deceleration limit, the PSD (a082) will be set.
|
No
|
|
|
iBooster (IBST) read failed failure for parameter MasterCylinderLength.
|
IBST read failed failure for parameter MasterCylinderLength.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected the find idle routine in plant failed.
|
IBST detected the find idle routine in plant failed.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected find idle data can not be written in the find idle calibration routine in plant/service (Rotation Position Sensor (RPS) angle at backward bound and idle and lips IDs).
|
IBST detects find idle data can not be written in the find idle calibration routine in plant/service.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Non-volatile Memory (NvM) value for the GapLap JI-Adjust is not readable.
|
IBST detects NvM value for the GapLap JI-Adjust is not readable.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected backward bound could not be detected during greasing routine, resulting in a time out.
|
IBST detected backward bound can not be detected during greasing routine - Time out.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected charge Pump Tests/Monitor could not be executed due to an undervoltage condition.
|
IBST detected charge Pump Tests/Monitor could not be executed due to an undervoltage condition.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Brushless Motor (BLM) temperature sensors are not plausible voltage values.
|
IBST detects a BLM temperatures are not plausible voltage value.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 1 line shorted to supply.
|
IBST detects BLM temperature sensor 1 line shorted to supply.o
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to ground.
|
IBST detects BLM temperature sensor 2 line shorted to ground.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 1 line shorted to ground.
|
IBST detects BLM temperature sensor 1 line shorted to ground.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to supply.
|
IBST detects BLM temperature sensor 2 line shorted to supply.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to TLE9180 bridge driver Application-Specific Integrated Circuit (ASIC) has failed (error frame wrong address or timeout CSIH error).
|
IBST detected SPI transfer to TLE9180 bridge driver ASIC has failed.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a failure word where Electrically Erasable Programmable Read-Only Memory (EEPROM) size detection failed or EEPROM size does not match configured size and actual size mounted on layout.
|
IBST detects a failure word where EEPROM size detection failed or EEPROM size does not match configured size and actual size mounted on layout.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a failure word event where write/erase service was requested sporadically.
|
IBST detects write/erase service is being requested sporadically.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected an Analog-to-Digital Converter (ADC) register bit has flipped or is stuck.
|
IBST detects an ADC register bit has flipped or is stuck.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a UB6 to UBB plausi voltage divider drift failure (large deviation in the UB6 to UBB ratio).
|
IBST detected a UB6 to UBB plausi voltage divider drift failure.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected high ohmic UB6 path (a large deviation between UB6 & UBB during motor actuation).
|
IBST detects a high ohmic UB6 path.
|
IBST may not operate as expected.
|
No
|