Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
iBooster (IBST) detected UBB voltage is in undervoltage level 2 failure range. System shall be in 'ReducedPerformance' state.
|
IBST detected UBB voltage is in undervoltage level 2 failure range. System shall be in 'ReducedPerformance' state.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a BusOff failure on Controller Area Network (CAN) 2 (CHASSIS).
|
IBST detects a BusOff failure on CAN 2 (CHASSIS)
|
IBST may not operate as expected.
|
No
|
|
|
CiBooster (IBST) detected a BusOff failure on Controller Area Network (CAN) 1 (PARTY).
|
IBST detects a BusOff failure on CAN 1 (PARTY)
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a linear position sensor channel 1 sensor internal failure.
|
IBST detected a linear position sensor channel 1 sensor internal failure.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor channel 1 failure in Single Edge Nibble Transmission (SENT) protocol.
|
IBST detects linear position sensor channel 1 failure in SENT protocol.
|
IBST may not operate as expected.
|
No
|
|
|
The CAN Bus status is monitored cyclically, whenever there is a short circuit between CAN-H and CAN-L or a heavy bus disturbance which leads to BusOff, the fault is registered
|
ESP is not receiving any message traffic on BRAKE bus
|
Vehicle hold and AutoPilot disabled
|
No
|
|
|
iBooster (IBST) detected the ASW configuration took too long
|
IBST detects ASW configuration is taking too long.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a migration process failure due to power interruption in previous power cycle or a migration was not possible due to insufficient space available on Electrically Erasable Programmable Read-Only Memory (EEPROM).
|
IBST detects a migration process failure due to power interruption in previous power cycle or a migration was not possible due to insufficient space available on EEPROM.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor channel 1 line shorted to ground.
|
IBST detects linear position sensor channel 1 line shorted to ground.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor channel 1 line shorted to supply or interruption of sensor ground.
|
IBST detects linear position sensor channel 1 line shorted to supply or interruption of sensor ground.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor channel 2 duty or period is out of range.
|
IBST detects linear position sensor channel 2 duty or period is out of range.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor channel 2 line shorted to ground.
|
IBST detects linear position sensor channel 2 line shorted to ground.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor channel 2 line shorted to supply or interruption of sensor ground.
|
IBST detects linear position sensor channel 2 line shorted to supply or interruption of sensor ground.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a linear position sensor 5V supply error.
|
IBST detected a linear position sensor 5V supply error.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected linear position sensor 5V supply undervoltage caused by 12V undervoltage.
|
IBST detected linear position sensor 5V supply undervoltage caused by 12V undervoltage.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected a error in metal-oxide-semiconductor field-effect transistor (MOSFET) bridge driver shorted detection.
|
IBST detects an error in MOSFET bridge driver shorted detection.
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected offset current 1 out of range (low).
|
IBST detects offset current 1 out of range (low).
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected offset current 1 out of range (high).
|
IBST detects offset current 1 out of range (high).
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected offset current 2 out of range (low).
|
IBST detects offset current 2 out of range (low).
|
IBST may not operate as expected.
|
No
|
|
|
iBooster (IBST) detected offset current 2 out of range (high).
|
IBST detects offset current 2 out of range (high).
|
IBST may not operate as expected.
|
No
|