| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Bosch DTC value: 0x0000E800
|
|
-
|
|
|
Bosch DTC value: 0x0000E300
|
|
-
|
|
|
Bosch DTC value: 0x0000E200
|
|
-
|
|
|
Bosch DTC value: 0x0000E100
|
|
-
|
|
|
Bosch DTC value: 0x0000DD00
|
|
-
|
|
|
The CAN Bus status is monitored cyclically, whenever there is a short circuit between CAN-H and CAN-L or a heavy bus disturbance which leads to BusOff, the fault is registered
|
ESP is not receiving any message traffic on BRAKE bus
|
Vehicle hold and AutoPilot disabled
|
|
|
iBooster (IBST) detected the ASW configuration took too long
|
IBST detects ASW configuration is taking too long.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) test of the charge pump has detected a failure.
|
IBST test of the charge pump has detected a failure.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected an application-specific integrated circuit (ASIC) internal error.
|
IBST detects an ASIC internal error.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected an application-specific integrated circuit (ASIC) internal error.
|
IBST detects an ASIC internal error.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected data reception did not complete within the expected time interval.
|
IBST detected data reception did not complete within the expected time interval.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected data reception did not complete within the expected time interval.
|
IBST detected data reception did not complete within the expected time interval.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected an ECU output (UEXS) over-temperature condition and has been switched off.
|
UEXS has over-temperature and has been switched off.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected maximum allowed time to start the system has been reached.
|
IBST detects maximum allowed time to start the system is reached.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected an SMM information failure.
|
IBST detects an SMM information failure.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected Rotation Position Sensor (RPS) Cos+ or Cos-signal too high.
|
IBST detected RPS Cos+ or Cos-signal too high.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected Rotation Position Sensor (RPS) Sin+ or Sin-signal too high.
|
IBST detected RPS Sin+ or Sin- signal too high.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected Rotation Position Sensor (RPS) Cos+ or Cos-signal too low.
|
IBST detected RPS Cos+ or Cos-signal too low.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected Rotation Position Sensor (RPS) Sin+ or Sin- signal too low.
|
IBST detected RPS Sin+ or Sin- signal too low.
|
IBST may not operate as expected.
|
|
|
iBooster (IBST) detected UBB voltage is above shutdown threshold (overvoltage level 3).
|
IBST detected UBB voltage is above shutdown threshold.
|
IBST may not operate as expected.
|