iBooster (IBST) detected a failure in the metal-oxide-semiconductor field-effect transistor (MOSFET) bridge driver supply switch.
IBST detects a failure in MOSFET bridge driver supply switch.
IBST may not operate as expected.
No
iBooster (IBST) detected a bridge metal-oxide-semiconductor field-effect transistor (MOSFET) shorted error.
IBST detects a bridge MOSFET shorted error.
IBST may not operate as expected.
No
iBooster (IBST) detected an application-specific integrated circuit (ASIC) internal error.
IBST detects an ASIC internal error.
IBST may not operate as expected.
No
iBooster (IBST) detected an application-specific integrated circuit (ASIC) internal error.
IBST detects an ASIC internal error.
IBST may not operate as expected.
No
iBooster (IBST) detected data reception did not complete within the expected time interval.
IBST detected data reception did not complete within the expected time interval.
IBST may not operate as expected.
No
iBooster (IBST) detected data reception did not complete within the expected time interval.
IBST detected data reception did not complete within the expected time interval.
IBST may not operate as expected.
No
iBooster (IBST) detected an ECU output (UEXS) over-temperature condition and has been switched off.
UEXS has over-temperature and has been switched off.
IBST may not operate as expected.
No
iBooster (IBST) detected maximum allowed time to start the system has been reached.
IBST detects maximum allowed time to start the system is reached.
IBST may not operate as expected.
No
iBooster (IBST) detected an SMM information failure.
IBST detects an SMM information failure.
IBST may not operate as expected.
No
iBooster (IBST) detected Rotation Position Sensor (RPS) Cos+ or Cos-signal too high.
IBST detected RPS Cos+ or Cos-signal too high.
IBST may not operate as expected.
No
iBooster (IBST) detected Rotation Position Sensor (RPS) Sin+ or Sin-signal too high.
IBST detected RPS Sin+ or Sin- signal too high.
IBST may not operate as expected.
No
iBooster (IBST) detected Rotation Position Sensor (RPS) Cos+ or Cos-signal too low.
IBST detected RPS Cos+ or Cos-signal too low.
IBST may not operate as expected.
No
iBooster (IBST) detected Rotation Position Sensor (RPS) Sin+ or Sin- signal too low.
IBST detected RPS Sin+ or Sin- signal too low.
IBST may not operate as expected.
No
iBooster (IBST) detected UBB voltage is above shutdown threshold (overvoltage level 3).
IBST detected UBB voltage is above shutdown threshold.
IBST may not operate as expected.
No
iBooster (IBST) detected UBB supply voltage is below shutdown threshold (undervoltage level 3).
IBST detected UBB supply voltage is below shutdown threshold.
IBST may not operate as expected.
No
iBooster (IBST) Controller Area Network (CAN)-Driver: Timeout caused by Hardware (HW)-Error (CAN-Controller configuration failed).
IBST detects CAN-Driver Timeout caused by a HW-Error.
IBST may not operate as expected.
No
iBooster (IBST) detected spindle position value is higher than the physical limited values.
IBST detected spindle position value is higher than the physical limited values.
IBST may not operate as expected.
No
iBooster (IBST) detected a permanent deviation between the target speed and the actual motor speed.
IBST detected a permanent deviation between the target speed and the actual motor speed.
IBST may not operate as expected.
No
iBooster (IBST) detected differential travel is permanently not compensated.
IBST detected differential travel is permanently not compensated.
IBST may not operate as expected.
No
iBooster (IBST) firmware set in case of temperature degradation level 2.
IBST firmware set in case of temperature degradation level 2.
IBST may not operate as expected.
No