Alerts

Alerts

Signal Name Description Condition Impact
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 1 line shorted to ground.
IBST detects BLM temperature sensor 1 line shorted to ground.
IBST may not operate as expected.
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to supply.
IBST detects BLM temperature sensor 2 line shorted to supply.
IBST may not operate as expected.
iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to TLE9180 bridge driver Application-Specific Integrated Circuit (ASIC) has failed (error frame wrong address or timeout CSIH error).
IBST detected SPI transfer to TLE9180 bridge driver ASIC has failed.
IBST may not operate as expected.
iBooster (IBST) detected the ASW configuration took too long.
IBST detects ASW configuration is taking too long.
IBST may not operate as expected.
iBooster (IBST) detected a migration process failure due to power interruption in previous power cycle or a migration was not possible due to insufficient space available on Electrically Erasable Programmable Read-Only Memory (EEPROM).
IBST detects a migration process failure due to power interruption in previous power cycle or a migration was not possible due to insufficient space available on EEPROM.
IBST may not operate as expected.
iBooster (IBST) detected a failure word where Electrically Erasable Programmable Read-Only Memory (EEPROM) size detection failed or EEPROM size does not match configured size and actual size mounted on layout.
IBST detects a failure word where EEPROM size detection failed or EEPROM size does not match configured size and actual size mounted on layout.
IBST may not operate as expected.
iBooster (IBST) detected a failure word event where write/erase service was requested sporadically.
IBST detects write/erase service is being requested sporadically.
IBST may not operate as expected.
iBooster (IBST) detected an Analog-to-Digital Converter (ADC) register bit has flipped or is stuck.
IBST detects an ADC register bit has flipped or is stuck.
IBST may not operate as expected.
iBooster (IBST) detected a UB6 to UBB plausi voltage divider drift failure (large deviation in the UB6 to UBB ratio).
IBST detected a UB6 to UBB plausi voltage divider drift failure.
IBST may not operate as expected.
iBooster (IBST) detected high ohmic UB6 path (a large deviation between UB6 & UBB during motor actuation).
IBST detects a high ohmic UB6 path.
IBST may not operate as expected.
iBooster (IBST) detected a condition in the Analog-to-Digital Converter (ADC) peripheral.
IBST detects a condition in the ADC peripheral.
IBST may not operate as expected.
iBooster (IBST) Analog-to-Digital Converter (ADC) self test C5P detected a failure.
IBST ADC self test C5P detects a failure.
IBST may not operate as expected.
iBooster (IBST) Analog-to-Digital Converter (ADC) pin test detected an open ADC pin.
IBST ADC pin test detects an open ADC pin.
IBST may not operate as expected.
iBooster (IBST) detected and Electronic Control Unit (ECU) bandgap failure.
IBST ECU Badgap failure detected.
IBST may not operate as expected.
iBooster (IBST) detected a Voltage Precharge (VPRE) external feed. An internal short-circuit condition may have occurred.
IBST detects VPRE was fed externally.
IBST may not operate as expected.
iBooster (IBST) task monitor reports an error status.
IBST task monitor reports an error status.
IBST may not operate as expected.
iBooster (IBST) detected an error in dual core SW Built-In Self Test (BIST) comparison.
IBST detects dual core SW BIST comparison error.
IBST may not operate as expected.
iBooster (IBST) detected at least one command number for safe backbone monitoring not scheduled from Application-Specific Integrated Circuit (ASIC) watchdog.
IBST detected at least one command number for safe backbone monitoring not scheduled from ASIC watchdog.
IBST may not operate as expected.
iBooster (IBST) detected the number of watchdog trigger patterns is too high.
IBST detected the number of watchdog trigger patterns is too high.
IBST may not operate as expected.
iBooster (IBST) detected watchdog on Application-Specific Integrated Circuit (ASIC) does not react on incorrect trigger pattern.
IBST detects watchdog on ASIC does not react on incorrect trigger pattern.
IBST may not operate as expected.