IBST_a055_UB6SupplyPathFault
Description
iBooster (IBST) detected high ohmic UB6 path (a large deviation between UB6 & UBB during motor actuation).
Condition
IBST detects a high ohmic UB6 path.
Clear Condition
iBooster can not recover from this condition. iBooster replacement may be required.
Potential Impact
IBST may not operate as expected.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+