iBooster (IBST) detected a condition in the Analog-to-Digital Converter (ADC) peripheral.
IBST detects a condition in the ADC peripheral.
IBST may not operate as expected.
No
iBooster (IBST) Analog-to-Digital Converter (ADC) self test C5P detected a failure.
IBST ADC self test C5P detects a failure.
IBST may not operate as expected.
No
iBooster (IBST) Analog-to-Digital Converter (ADC) pin test detected an open ADC pin.
IBST ADC pin test detects an open ADC pin.
IBST may not operate as expected.
No
iBooster (IBST) detected and Electronic Control Unit (ECU) bandgap failure.
IBST ECU Badgap failure detected.
IBST may not operate as expected.
No
iBooster (IBST) detected a Voltage Precharge (VPRE) external feed. An internal short-circuit condition may have occurred.
IBST detects VPRE was fed externally.
IBST may not operate as expected.
No
iBooster (IBST) task monitor reports an error status.
IBST task monitor reports an error status.
IBST may not operate as expected.
No
iBooster (IBST) detected an error in dual core SW Built-In Self Test (BIST) comparison.
IBST detects dual core SW BIST comparison error.
IBST may not operate as expected.
No
iBooster (IBST) detected at least one command number for safe backbone monitoring not scheduled from Application-Specific Integrated Circuit (ASIC) watchdog.
IBST detected at least one command number for safe backbone monitoring not scheduled from ASIC watchdog.
IBST may not operate as expected.
No
iBooster (IBST) detected the number of watchdog trigger patterns is too high.
IBST detected the number of watchdog trigger patterns is too high.
IBST may not operate as expected.
No
iBooster (IBST) detected watchdog on Application-Specific Integrated Circuit (ASIC) does not react on incorrect trigger pattern.
IBST detects watchdog on ASIC does not react on incorrect trigger pattern.
IBST may not operate as expected.
No
iBooster (IBST) detected a failure word in case of write service to Electrically Erasable Programmable Read-Only Memory (EEPROM) was unable to complete in expected time interval.
IBST detects a failure word in case of write service to EEPROM was unable to complete in expected time interval.
IBST may not operate as expected.
No
iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to Application-Specific Integrated Circuit (ASIC) failed. Condition can occur due to an error frame incorrect address or timeout CSIH error.
IBST detects SPI transfer to ASIC has failed.
IBST may not operate as expected.
No
iBooster (IBST) detected Application-Specific Integrated Circuit (ASIC) initialization test failed during the initialization task.
IBST detected ASIC initialization test failed during the initialization task.
IBST may not operate as expected.
No
iBooster (IBST) detected an internal non-serviceable condition with the Clock Input (CLKIN) on its Application-Specific Integrated Circuit (ASIC).
IBST detects an internal non-serviceable condition with CLKIN on its ASIC.
IBST may not operate as expected.
No
iBooster (IBST) detected a Generic Timer Module (GTM) reference frequency error.
IBST detects a GTM reference frequency error.
IBST may not operate as expected.
No
iBooster (IBST) detected a Generic Timer Module (GTM) reference frequency error.
IBST detects a GTM reference frequency error.
IBST may not operate as expected.
No
iBooster (IBST) continuous monitor of enable lines detected a missing (low) enable signal.
IBST continuous monitor of enable lines detected a missing (low) enable signal.
IBST may not operate as expected.
No
iBooster (IBST) detected watchdog status of system integrate circuit (IC) deviates from the expected status.
IBST detects watchdog status of system IC deviates from expected status.
IBST may not operate as expected.
No
iBooster (IBST) detected control over MRG via EN_HY or MRAUC or both is not functional.
IBST detects control over MRG via EN_HY or MRAUC or both is notn functional.
IBST may not operate as expected.
No
iBooster (IBST) detected the hydraulic enable line is unable to switch off via the uC and via the system Integrated Circuit (IC).
IBST hydraulic enable is unable to switch off via the uC port and system IC.
IBST may not operate as expected.
No