IBST_a067_tempSensImplausVoltage
Description
iBooster (IBST) detected Brushless Motor (BLM) temperature sensors are not plausible voltage values.
Condition
IBST detects a BLM temperatures are not plausible voltage value.
Clear Condition
iBooster can not recover from this condition. iBooster replacement may be required.
Potential Impact
IBST may not operate as expected.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+