BCFALCD_w101_VbatUnplugged
|
If one of the VBAT inputs is not available
|
door limited to 1 cycle per minute
|
|
|
Latch cinch has timed out. Releasing the latch to prevent latch hardware fault.
|
Latch cinch has timed out and a latch release command has been sent
|
Latch cinching failed, new door close attempt required to close the door
|
|
|
The Falcon Door Body Controller has detected actuators are being driven with an unexpected duty cycle.
|
Actuators are being driven with an unexpected duty cycle while door has been CLOSED for > 5 seconds.
|
Continued abnormality puts actuators at risk of overheating, potentially damaging components and reducing lifespan.
|
|
|
Falcon door latch reported closed while the Falcon door is open and not detected near the closed position.
|
Latch reported closed while the Falcon door was not near the door closed position.
|
Falcon door will stop and loose its calibration.
|
|
|
Falcon door obstacle detection overriden by user.
|
Sensor override mode enabled by holding one of the Falcon door open or close switch for 1000 ms.
|
Falcon door movement will ignore most obstacle sensor input and door motion will be slower.
|
|
|
The Falcon door controller detects requested movement for the door is rejected.
|
The movement request for the Falcon door is rejected. Alert log signal data should provide more information on the specific condition detected.
|
The Falcon door will not reach the requested position.
|
|
|
BCFALCD_w091_CrashStateMismatch
|
BDY_RCM_collision did not match BDY_BCCEN_collision
|
If any crash signal is active, crash behavior is active
|
|
|
BCFALCD_w090_CrashUnlockError
|
Vehicle did not unlock after crash.
|
These are the repercussions of the alert being set
|
|
|
The Falcon door controller detects the door stops unexpectedly while moving to the requested position.
|
The Falcon door stops unexpectedly while moving to the requested position. Alert log signal data should provide more information on the specific condition detected.
|
The Falcon door will not reach the requested position.
|
|
|
Firmware compensation for actuator brakes out of spec.
|
Active sag compensation
|
If this occurs often, struts should be replaced
|
|
|
The Falcon door needs to be calibrated, which can be done by holding the B pillar close switch until ~2 seconds after door is latched.
|
Falcon door has never been calibrated, or calibration has been lost due to unexpected event like 12V loss or unexpected latch closing.
|
Uncalibrated doors will not respond to movement commands and triple beep.
|
|
|
The Falcon door controller detected a condition affecting the functionality of one or both of the pinch strips.
|
One or both of the pinch strips are continuously reported as disconnected or pressed, or return invalid voltage values.
|
The Falcon door pinch strips may not perform as designed.
|
|
|
Check SNS USS_alertMatrix for specific details of this alert
|
When there is an overshoot in ECU's voltage levels.
|
-
|
|
|
Check SNS USS_alertMatrix for specific details of this alert
|
When the ECU's voltage drops belowe threshold.
|
-
|
|
|
Check SNS USS_alertMatrix for specific details of this alert
|
When there is a LIN communication error.
|
-
|
|
|
The inward-facing Ultrasonic Sensor (USS) located on the right Falcon Door has encountered a hardware failure.
|
Alert log signal data should provide further information on specific condition(s) involved.
|
Malfunctioning hardware in the right Falcon Door's internal ultrasonic sensor can result in intermittent or total loss of functionality of the USS.
|
|
|
The inward-facing Ultrasonic Sensor (USS) located on the left Falcon Door has encountered a hardware failure.
|
Alert log signal data should provide further information on specific condition(s) involved.
|
Malfunctioning hardware in the left Falcon Door's internal ultrasonic sensor can result in intermittent or total loss of functionality of the USS.
|
|
|
Communication through Local Interconnect Network (LIN) with the right-side inward-facing Ultrasonic Sensor (USS) in the Falcon Door System has been disconnected or interrupted.
|
LIN communication between the Falcon Door and left Falcon door's inner ultrasonic sensor has been disconnected or interrupted.
|
Loss of LIN communication can impact Falcon Door system functionality including obstructive awareness, motion management, and protection mechanisms.
|
|
|
Failure of the Falcon Door Ultrasonic Sensor (USS) Hardware Watchdog Timer detected.
|
The designated hardware watchdog timer tasked with monitoring USS equipment fails to perform its duties correctly.
|
Timer failure may cause erratic behavior, total failure, or diminished performance in USS operations.
|
|
|
The CAN bus connected to the Falcon Door Ultrasonic Sensor (USS) has been detected as offline.
|
Occurs whenever the CAN bus responsible for USS communication shuts down unexpectedly or intentionally.
|
An offline CAN bus can lead to intermittent faltering, complete failure, or decreased performance in ultrasonic sensor functionality.
|