Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
|
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
|
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
|
No
|
|
|
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
|
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
|
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
|
No
|
|
|
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
|
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
|
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
|
No
|
|
|
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
|
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
|
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
|
No
|
|
|
BCFALCD_w174_USSRoofResonanceErr
|
Resonance Period reported by the roof Ultrasonic is out-of-bounds
|
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
|
No
|
|
|
BCFALCD_w175_USSRoofReverbErr
|
Reverb time reported by the roof Ultrasonic is out-of-bounds
|
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
|
No
|
|
|
BCFALCD_w176_USSRoofNotCaptured
|
Roof Ultrasonic parameters are not captured
|
-
|
No
|
|
|
The Falcon Door Body Controller has detected the resonance period reported by the ultrasonic sensor is out of bounds.
|
The ultrasonic sensor reports a resonance period outside of the expected range.
|
The ultrasonic sensor may be unable to detect obstacles in the door's path.
|
No
|
|
|
BCFALCD_w178_USSDoorReverbErr
|
Reverb time reported by the door Ultrasonic is out-of-bounds
|
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
|
No
|
|
|
BCFALCD_w179_USSDoorNotCaptured
|
Door Ultrasonic parameters are not captured
|
-
|
No
|
|
|
The Falcon Door Body Controller has detected the electrical current limit for the upper actuator has been exceeded.
|
The actuator's electrical current has been exceeded.
|
An obstruction may be impacting functionality or a strut may be damaged.
|
No
|
|
|
The Falcon Door Body Controller has detected the door section is deviating by 6 degrees away from its designated trajectory target path.
|
The door section is deviating by 6 degrees away from its designated trajectory target path.
|
Multiple occurrences suggest possible hardware conditions in the door or interference from foreign objects and debris affecting door functionality.
|
No
|
|
|
The Falcon Door Body Controller has detected a deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure at a speed of 7 degrees per second.
|
Deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure of 7 degrees per second is detected.
|
Multiple occurrences suggest possible hardware conditions in the door or interference from foreign objects and debris affecting door functionality.
|
No
|
|
|
The Falcon Door Body Controller has detected the electrical current limit for the lower actuator's electrical current has been exceeded.
|
The actuator's electrical current has been exceeded.
|
An obstruction may be impacting functionality or a strut may be damaged.
|
No
|
|
|
Failure of the Falcon Door Ultrasonic Sensor (USS) Hardware Watchdog Timer detected.
|
The designated hardware watchdog timer tasked with monitoring USS equipment fails to perform its duties correctly.
|
Timer failure may cause erratic behavior, total failure, or diminished performance in USS operations.
|
No
|
|
|
Check OTP region of DFLASH
|
Error reading from OTP.
|
Genealogy information may not be read.
|
No
|
|
|
BCFALCD_w110_InteriorOpenSwitch
|
Switch active for 30 seconds continuously, or has faulted.
|
Switch input ignored if faulted
|
No
|
|
|
Log contains stack usage for each task.
|
Stack usage exceeds 80% for any task.
|
Stack overflow can occur if there is not enough stack space.
|
No
|
|
|
Log contains CPU load for each task.
|
CPU load exceeds 80%.
|
High CPU load can indicate ineffecient code.
|
No
|
|
|
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
|
ECU Debug Jumper is set.
|
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
|
No
|