Signal Name Description Condition Impact
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
BCFALCD_w174_USSRoofResonanceErr
Resonance Period reported by the roof Ultrasonic is out-of-bounds
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
BCFALCD_w175_USSRoofReverbErr
Reverb time reported by the roof Ultrasonic is out-of-bounds
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
BCFALCD_w176_USSRoofNotCaptured
Roof Ultrasonic parameters are not captured
-
The Falcon Door Body Controller has detected the resonance period reported by the ultrasonic sensor is out of bounds.
The ultrasonic sensor reports a resonance period outside of the expected range.
The ultrasonic sensor may be unable to detect obstacles in the door's path.
BCFALCD_w178_USSDoorReverbErr
Reverb time reported by the door Ultrasonic is out-of-bounds
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
BCFALCD_w179_USSDoorNotCaptured
Door Ultrasonic parameters are not captured
-
The Falcon Door Body Controller has detected the electrical current limit for the upper actuator has been exceeded.
The actuator's electrical current has been exceeded.
An obstruction may be impacting functionality or a strut may be damaged.
The Falcon Door Body Controller has detected the door section is deviating by 6 degrees away from its designated trajectory target path.
The door section is deviating by 6 degrees away from its designated trajectory target path.
Multiple occurrences suggest possible hardware conditions in the door or interference from foreign objects and debris affecting door functionality.
The Falcon Door Body Controller has detected a deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure at a speed of 7 degrees per second.
Deviation from the desired speed of the door section during opening at a rate of 9 degrees per second or upon closure of 7 degrees per second is detected.
Multiple occurrences suggest possible hardware conditions in the door or interference from foreign objects and debris affecting door functionality.
The Falcon Door Body Controller has detected the electrical current limit for the lower actuator's electrical current has been exceeded.
The actuator's electrical current has been exceeded.
An obstruction may be impacting functionality or a strut may be damaged.
Communication through Local Interconnect Network (LIN) with the left-side inward-facing Ultrasonic Sensor (USS) in the Falcon Door System has been disconnected or interrupted.
LIN communication between the Falcon Door and left Falcon door's inner ultrasonic sensor has been disconnected or interrupted.
Loss of LIN communication can impact Falcon Door system functionality including obstructive awareness, motion management, and protection mechanisms.
Check OTP region of DFLASH
Error reading from OTP.
Genealogy information may not be read.
BCFALCD_w110_InteriorOpenSwitch
Switch active for 30 seconds continuously, or has faulted.
Switch input ignored if faulted
Log contains stack usage for each task.
Stack usage exceeds 80% for any task.
Stack overflow can occur if there is not enough stack space.
Log contains CPU load for each task.
CPU load exceeds 80%.
High CPU load can indicate ineffecient code.
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
ECU Debug Jumper is set.
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.