Signal Name Description Condition Impact
BCFALCP_w178_USSDoorReverbErr
Reverb time reported by the door Ultrasonic is out-of-bounds
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
The Falcon Door Body Controller has detected the resonance period reported by the ultrasonic sensor is out of bounds.
The ultrasonic sensor reports a resonance period outside of the expected range.
The ultrasonic sensor may be unable to detect obstacles in the door's path.
BCFALCP_w176_USSRoofNotCaptured
Roof Ultrasonic parameters are not captured
-
BCFALCP_w175_USSRoofReverbErr
Reverb time reported by the roof Ultrasonic is out-of-bounds
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
BCFALCP_w174_USSRoofResonanceErr
Resonance Period reported by the roof Ultrasonic is out-of-bounds
Out of bounds Value from the Ultrasonics may cause the door to not detect obstacles
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).
Section actuator temperature model has exceeded 100.0 deg C (212 deg F).
Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.
One of the two Falcon pinch strip sensor was pressed and stopped the door movement.
Pinch strip was pressed while the door was moving or when a movement request was received.
Falcon door will either stop if in motion, or reject movement request if static.
BCFALCP_w164_InductivObsDetected
At least one sensor detects an obstacle
obstacles will change the closing path
BCFALCP_w163_CapacitObsDetected
At least one sensor detects an obstacle
obstacles will change the opening path
BCFALCP_w162_RoofUSSObsDetected
At least one sensors detects an obstacle
obstacles will change the opening path
BCFALCP_w161_DoorUSSObsDetected
At least one sensors detects an obstacle
obstacles will change the opening path
The Falcon Door Body Controller Inertial Measurement Unit (IMU) has detected an obstacle and stopped door motion.
IMU has detected an obstacle and stopped door motion.
Door motion would be stopped.
BCFALCP_w159_IMUSensitiveTrigger
IMU reports an acceleration of greater than 0.8g
The alert is for engineering diagnosis. Impact is still TBD
The Falcon Door Body Controller has detected lower rear actuator current limit has been surpassed for more than 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
The lower rear actuator experienced a current limit surge lasting for over 100 milliseconds and exceeds 19A.
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.
The Falcon Door Body Controller has detected the lower front actuator current limit has been surpassed for more than 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
The lower front actuator experienced a current limit surge lasting for over 100 milliseconds and exceeds 19A.
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.
The Falcon Door Body Controller has detected the upper rear actuator experienced a current limit surge lasting for over 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
The upper rear actuator experienced a current limit surge lasting for over 100 milliseconds and exceeding 19A.
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.
The Falcon Door Body Controller has detected the upper front actuator experienced a current limit surge lasting for over 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
The upper front actuator experienced a current limit surge lasting for over 100 milliseconds and exceeding 19A.
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.