BCFALCP_w147_lowerRearCurLimit
Description
The Falcon Door Body Controller has detected lower rear actuator current limit has been surpassed for more than 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.
Condition
The lower rear actuator experienced a current limit surge lasting for over 100 milliseconds and exceeds 19A.
Clear Condition
Lower rear actuator operates within normal current limits without experiencing any surges.
Potential Impact
Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.
Customer Facing Message 1
Falcon door motion interrupted
Customer Facing Message 2
Retry or manually move door
Audiences
service
Models
Model S 2012-2020;Model X 2015-2020