| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
The Falcon door controller detects the door stops unexpectedly while moving to the requested position.
|
The Falcon door stops unexpectedly while moving to the requested position. Alert log signal data should provide more information on the specific condition detected.
|
The Falcon door will not reach the requested position.
|
|
|
Firmware compensation for actuator brakes out of spec.
|
Active sag compensation
|
If this occurs often, struts should be replaced
|
|
|
The Falcon door needs to be calibrated, which can be done by holding the B pillar close switch until ~2 seconds after door is latched.
|
Falcon door has never been calibrated, or calibration has been lost due to unexpected event like 12V loss or unexpected latch closing.
|
Uncalibrated doors will not respond to movement commands and triple beep.
|
|
|
The Falcon door controller detected a condition affecting the functionality of one or both of the pinch strips.
|
One or both of the pinch strips are continuously reported as disconnected or pressed, or return invalid voltage values.
|
The Falcon door pinch strips may not perform as designed.
|
|
|
The inward-facing Ultrasonic Sensor (USS) located on the right Falcon Door has encountered a hardware failure.
|
Alert log signal data should provide further information on specific condition(s) involved.
|
Malfunctioning hardware in the right Falcon Door's internal ultrasonic sensor can result in intermittent or total loss of functionality of the USS.
|
|
|
The inward-facing Ultrasonic Sensor (USS) located on the left Falcon Door has encountered a hardware failure.
|
Alert log signal data should provide further information on specific condition(s) involved.
|
Malfunctioning hardware in the left Falcon Door's internal ultrasonic sensor can result in intermittent or total loss of functionality of the USS.
|
|
|
Communication through Local Interconnect Network (LIN) with the right-side inward-facing Ultrasonic Sensor (USS) in the Falcon Door System has been disconnected or interrupted.
|
LIN communication between the Falcon Door and left Falcon door's inner ultrasonic sensor has been disconnected or interrupted.
|
Loss of LIN communication can impact Falcon Door system functionality including obstructive awareness, motion management, and protection mechanisms.
|
|
|
Communication through Local Interconnect Network (LIN) with the left-side inward-facing Ultrasonic Sensor (USS) in the Falcon Door System has been disconnected or interrupted.
|
LIN communication between the Falcon Door and left Falcon door's inner ultrasonic sensor has been disconnected or interrupted.
|
Loss of LIN communication can impact Falcon Door system functionality including obstructive awareness, motion management, and protection mechanisms.
|
|
|
Failure of the Falcon Door Ultrasonic Sensor (USS) Hardware Watchdog Timer detected.
|
The designated hardware watchdog timer tasked with monitoring USS equipment fails to perform its duties correctly.
|
Timer failure may cause erratic behavior, total failure, or diminished performance in USS operations.
|
|
|
The Falcon Door Body Controller has detected actuators are being driven with an unexpected duty cycle.
|
Actuators are being driven with an unexpected duty cycle while door has been CLOSED for > 5 seconds.
|
Continued abnormality puts actuators at risk of overheating, potentially damaging components and reducing lifespan.
|
|
|
Latch cinch has timed out. Releasing the latch to prevent latch hardware fault.
|
Latch cinch has timed out and a latch release command has been sent
|
Latch cinching failed, new door close attempt required to close the door
|
|
|
BCFALCP_w101_VbatUnplugged
|
If one of the VBAT inputs is not available
|
door limited to 1 cycle per minute
|
|
|
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
|
ECU Debug Jumper is set.
|
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
|
|
|
Log contains CPU load for each task.
|
CPU load exceeds 80%.
|
High CPU load can indicate ineffecient code.
|
|
|
Log contains stack usage for each task.
|
Stack usage exceeds 80% for any task.
|
Stack overflow can occur if there is not enough stack space.
|
|
|
BCFALCP_w110_InteriorOpenSwitch
|
Switch active for 30 seconds continuously, or has faulted.
|
Switch input ignored if faulted
|
|
|
BCFALCP_w111_InteriorCloseSwitch
|
Switch active for 30 seconds continuously, or has faulted.
|
Switch input ignored if faulted
|
|
|
BCFALCP_w112_LatchEntryTimeout
|
Latch entry times out rather than cinching
|
The door hasn't successfully closed, but the user would have expected it to
|
|
|
Falcon door ultrasonic sensor (USS) is not communicating with the USS controller on the Local Interconnect Network (LIN) bus.
|
Falcon door outward ultrasonic sensor is not responding over LIN.
|
Falcon door obstacle detection and other features relying on ultrasonic sensor data will not function as expected.
|
|
|
BCFALCP_w123_capacitiveMIA
|
communication with the lower cladding is lost
|
obstacle detection from this sensor will not be available
|