Signal Name | Description | Condition | Impact |
---|---|---|---|
handle sleep efuse tripped.
|
handle sleep voltage is less than 6V
|
interior handles temporarily unavailable
|
|
Force sensor calibration is invalid.
|
Force sensor calibration is invalid
|
Loss of functionality due to system failure
|
|
The seat has detected that the track motor has exceeded normal operating times.
|
The operating time has exceeded 120 seconds within 5 minutes
|
The seat track motor will be disabled
|
|
Seat track motor abuse has been detected, with number of events within 5 minutes required to generate a warning exceeded.
|
The number of operating events per time period required to generate a warning for seat track motor abuse has been exceeded
|
The seat track motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded
|
|
The seat has detected that the track motor is close to exceeding normal operating times.
|
The operating time has exceeded 90 seconds within 5 minutes
|
The seat track motor will be disabled if operation is continued and exceeds 120 seconds within 5 minutes
|
|
The seat track abuse has been detected, maximum number of events per time exceeded.
|
The maximum number of operating events per time has been exceeded
|
The seat track motor will be disabled
|
|
Force sensor test pattern test failed & sensor raw vaues are out of range.
|
Force sensor test pattern test failed & sensor raw vaues are out of range
|
Loss of functionality due to functional safety checks
|
|
A Low Voltage (LV) battery brick voltage is below the under voltage Open-Circuit Voltage (OCV) limit at rest.
|
A battery pack brick voltage is below the under voltage OCV limit for longer than expected while contactors are open.
|
Drive may be blocked
|
|
Visor power supply is currently faulted.
|
Visor power supply is currently faulted
|
Loss of vanity light functionality
|
|
The right lower duct temperature sensor has an electrical fault.
|
The sensor is disconnected or short-circuited to ground
|
HVAC performance may be limited
|
|
Force sensor test pattern test failed & sensor raw vaues are out of range.
|
Force sensor test pattern test failed & sensor raw vaues are out of range
|
Loss of functionality due to functional safety checks
|
|
A Low Voltage (LV) battery brick voltage is less than the under voltage limit.
|
A battery pack brick voltage is below the under voltage limit for longer than expected.
|
Drive may be blocked
|
|
Rear dome power supply is currently faulted.
|
Rear dome power supply is currently faulted
|
Loss of vanity light functionality
|
|
Check for valid I2C force sensor communication.
|
FOHM detected invalid I2C force sensor communication
|
Loss of functionality due to functional safety checks
|
|
front exterior handle efuse tripped.
|
front exterior handle current sense is at 5V
|
front exterior handle temporarily unavailable
|
|
A battery pack brick voltage is above the warning voltage limit.
|
A battery pack brick voltage is above the warning voltage limit for longer than expected.
|
This alert is primarily informational and is used for logging purposes.
|
|
This ensures all the FOHM touch detection doesn't exceed the noise threshold.
|
FOHM detected an capacitive variance supervision failure
|
Loss of touch functionality due to functional safety checks
|
|
A battery pack brick State of Charge (SOC) is below the configured minimum threshold.
|
A battery pack brick SOC is below the minimum threshold while the pack is discharging
|
Drive may be blocked
|
|
Touch was detected for longer than 120s.
|
Touch was detected for longer than 120s
|
Loss of functionality due to functional safety checks
|
|
A Low Voltage (LV) battery pack brick voltage is greater than the over voltage limit.
|
A battery pack brick voltage is above the over voltage limit for longer than expected.
|
LV battery may be electrically disconnected from the LV system. Vehicle may be unable to drive.
|