Alerts

Alerts

Signal Name Description Condition Impact Important
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
setcondition
These are the repercussions of the alert being set
No
Not Available
Reasons to keep the controller awake have been the same for greater than one hour
The bus could not sleep causing significant range loss for the battery pack
No
Not Available
A signal is received 10% out of timing 3 times in a row.
These are the repercussions of the alert being set
No
After a record upgrade is successful, resetting the ECU should clear the alert.
Record not found, CRC mismatch, Version mismatch, Version upgrade.
Indicate the state of non-volatile data in the ECU.
No
Bridge faults are most likely due to configuration error.
An fault was reported by the bridge driver while initializing or controlling the bridge driver or a bridge channel.
Some or all bridge outputs may not opperate due to a bridge fault.
No
This alert is used to create the template for the raw alert log. Double check before this alert is used for something else.
Set condition
These are the repercussions of the alert being set
No
Encoder counts not changing
The track motor senses a failure in detecting movement
The track motor will be disabled
No
3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels
Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V
If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.
No
3930 Fault - Low Load Current. Senses less than 500mV
Track motor senses low current
Fault flag thrown, track motor will continue to work
No
3930 Fault - short to GND, short to Supply, shorted motor winding
Track motor detects a short
Comfort track and easy entry will be disabled
No
Check if 5V_SW is enabled at startup; check that the seatID pins are being set low in correspondance with the desired side; run UDS routine 204 on the bootloader to read and store the seat config
The ECU did not read the seat ID pins properly on reset
The ECU may not respond to the desired signals
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
No
Check latch cable, damaged microswitch, latch obstruction, latch motor damaged, latch motor harness, damaged ECU
The latch microswitch was not released after 1 second of driving the latch motor to unlatch or did not press after 1 second of driving the latch motor to latch and the pitch encoder count is greater than -10
The latch motor will be disabled
No
Seat temperature sensor may be disconnected, shorted, or faulted
The temperature sensor senses a fault and is either shorted or disconnected
The 3rd row seat heater may be disabled
No
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row center seat detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
No
The second row center seat heater is not heating as expected.
The seat heater duty cycle was set at 100% for 30 minutes.
Second row center seat heater will be unavailable.
No