Alerts

Alerts

Signal Name Description Condition Impact
Not Available
Response timeout of a LIN node
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
Not Available
setcondition
These are the repercussions of the alert being set
The SBC CAN transceiver has faulted. Alert will be seen if the trasnceiver has recovered from the faulted condition.
The BDY CAN bus communication is not available.
Other ECUs may report this ECU as being MIA and behaviour will be impacted. This alert won't be seen until CAN communcation has returned.
Not Available
Failure of a software assertion.
These are the repercussions of the alert being set
Undervoltage detection by the CPU can set this alert.
Sudden power loss.
These are the repercussions of the alert being set
This message contains separate signals for each watchdog reset source.
A watchdog (external or internal) was not serviced in time.
These are the repercussions of the alert being set
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
3rd row detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row detects occupancy sensor is in the faulted or disconnected voltage range
Occupant safety is impacted
Encoder counts not changing
The track motor senses a failure in detecting movement
The track motor will be disabled
3930 Fault - Under voltage, Overtemperature, Incorrect Logic Levels
Vreg < 8V, Overtemperature > 170 deg C on the A3930,Logic levels below lockout voltage level of 4V
If overtemperature, A3930 will continue to drive. If undervoltage or logic fault, motor control will be disabled.
3930 Fault - Low Load Current. Senses less than 500mV
Track motor senses low current
Fault flag thrown, track motor will continue to work
3930 Fault - short to GND, short to Supply, shorted motor winding
Track motor detects a short
Comfort track and easy entry will be disabled
Check if 5V_SW is enabled at startup; check that the seatID pins are being set low in correspondance with the desired side; run UDS routine 204 on the bootloader to read and store the seat config
The ECU did not read the seat ID pins properly on reset
The ECU may not respond to the desired signals
Seat temperature sensor may be disconnected, shorted, or faulted
The temperature sensor senses a fault and is either shorted or disconnected
The 3rd row seat heater may be disabled
Check latch cable, damaged microswitch, latch obstruction, latch motor damaged, latch motor harness, damaged ECU
The latch microswitch was not released after 1 second of driving the latch motor to unlatch or did not press after 1 second of driving the latch motor to latch and the pitch encoder count is greater than -10
The latch motor will be disabled
check occupancy sensor and harness, seat belt sensor and harness, damaged ECU
2nd row center seat detects buckle switch is in the faulted or disconnected voltage range
Occupant safety is impacted
A large voltage drop is detected in the input power to the vehicle controller, indicating the resistance on the input power feed to the vehicle controller is higher than expected.
Estimated resistance on the input power feed to the vehicle controller is higher than expected.
The vehicle controller may be unavailable due to lack of adequate input power, limiting vehicle functionality or making the vehicle inoperable, with at least one other alert specific to that condition present.