Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
alert data contains stop reason.
|
Set whenever the seat encounters an unexpected condition and movement stops
|
Seat movement will be stopped
|
|
Track will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine.
|
Track position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
|
Track motor will stop moving
|
|
Pitch will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine. AlertLog contains uncalibrated reason.
|
Pitch position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
|
Pitch motor will stop moving
|
|
The 2nd Row Left Seat Body Controller (BCS2L) detects the first row seat is not calibrated.
|
The BCS2L detects the first row seat is not calibrated.
|
Easy entry for the second row seat may be unavailable or may not function as expected.
|
|
Not Available
|
FILL_THIS_OUT
|
FILL_THIS_OUT
|
|
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
|
ECU Debug Jumper is set.
|
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
|
|
Log contains CPU load for each task.
|
CPU load exceeds 80%.
|
High CPU load can indicate ineffecient code.
|
|
Log contains stack usage for each task.
|
Stack usage exceeds 80% for any task.
|
Stack overflow can occur if there is not enough stack space.
|
|
Check seat temperature sensor for fault.
|
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
|
The 2nd row seat heater may be disabled
|
|
Check seat temperature sensor for fault.
|
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
|
The 2nd row seat heater may be disabled
|
|
Check seat heater pad for damage or disconnected seat heat pad wire.
|
When commanded on, the seat heater temperature has not risen 2 degC or more in the 45 seconds it has been powered on
|
The seat heater may not be operational or may have poor heating performance
|
|
Check seat heater pad for short, check other seat heater alerts as well.
|
Overcurrent, or current measurement error
|
The seat heater is disabled
|
|
Check seat heater pad for damage or disconnected seat heat pad wire.
|
When commanded on, the seat heater temperature has not risen 2 degC or more in the 45 seconds it has been powered on
|
The seat heater may not be operational or may have poor heating performance
|
|
The HSD will report a fault for any number of reasons, including: the HSD is overheating or the HSD power input is not stable, etc.
|
The HSD is self-reporting a fault
|
Seat heater pads will not be powered
|
|
Seat temperature sensor may be disconnected, shorted, or faulted.
|
The temperature sensor senses a fault and is either shorted or disconnected
|
The 2nd row seat heater may be disabled
|
|
Seat temperature sensor may be disconnected, shorted, or faulted.
|
The temperature sensor senses a fault and is either shorted or disconnected
|
The 3rd row seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 2nd row seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 3rd row seat heater may be disabled
|
|
Seat heater may be shorted, or faulted.
|
The current measured through the heater is more than expected
|
The 2nd row center seat heater may be disabled
|
|
Reconnect track sensor.
|
The track sensor senses a disconnect
|
Seat calibration will not work
|