Alerts

Alerts

Signal Name Description Condition Impact
alert data contains stop reason.
Set whenever the seat encounters an unexpected condition and movement stops
Seat movement will be stopped
Track will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine.
Track position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
Track motor will stop moving
Pitch will default to uncalibrated in new ECUs and can be set uncalibrated by UDS routine. AlertLog contains uncalibrated reason.
Pitch position calibration is checked and found to be uncalibrated at ECU power cycle, wake from sleep, etc
Pitch motor will stop moving
The 2nd Row Left Seat Body Controller (BCS2L) detects the first row seat is not calibrated.
The BCS2L detects the first row seat is not calibrated.
Easy entry for the second row seat may be unavailable or may not function as expected.
Not Available
FILL_THIS_OUT
FILL_THIS_OUT
Production vehicle should not have Debug Jumper in place. Remove jumper from ECU.
ECU Debug Jumper is set.
ECU Debug Jumper will disable SBC watchdog, preventing external watchdog reset protection.
Log contains CPU load for each task.
CPU load exceeds 80%.
High CPU load can indicate ineffecient code.
Log contains stack usage for each task.
Stack usage exceeds 80% for any task.
Stack overflow can occur if there is not enough stack space.
Check seat temperature sensor for fault.
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
The 2nd row seat heater may be disabled
Check seat temperature sensor for fault.
The heat pad is present, the temperature sensor is not disconnected and the value is less than -38 degC with a valid ambient reading of more than 10 degC, all for more than 3 seconds
The 2nd row seat heater may be disabled
Check seat heater pad for damage or disconnected seat heat pad wire.
When commanded on, the seat heater temperature has not risen 2 degC or more in the 45 seconds it has been powered on
The seat heater may not be operational or may have poor heating performance
Check seat heater pad for short, check other seat heater alerts as well.
Overcurrent, or current measurement error
The seat heater is disabled
Check seat heater pad for damage or disconnected seat heat pad wire.
When commanded on, the seat heater temperature has not risen 2 degC or more in the 45 seconds it has been powered on
The seat heater may not be operational or may have poor heating performance
The HSD will report a fault for any number of reasons, including: the HSD is overheating or the HSD power input is not stable, etc.
The HSD is self-reporting a fault
Seat heater pads will not be powered
Seat temperature sensor may be disconnected, shorted, or faulted.
The temperature sensor senses a fault and is either shorted or disconnected
The 2nd row seat heater may be disabled
Seat temperature sensor may be disconnected, shorted, or faulted.
The temperature sensor senses a fault and is either shorted or disconnected
The 3rd row seat heater may be disabled
Seat heater may be shorted, or faulted.
The current measured through the heater is more than expected
The 2nd row seat heater may be disabled
Seat heater may be shorted, or faulted.
The current measured through the heater is more than expected
The 3rd row seat heater may be disabled
Seat heater may be shorted, or faulted.
The current measured through the heater is more than expected
The 2nd row center seat heater may be disabled
Reconnect track sensor.
The track sensor senses a disconnect
Seat calibration will not work