Alerts

Alerts

Signal Name Description Condition Impact
Battery Management System Semi (BMSSEMI) detects subpack 3 state of charge (SOC) is below the threshold to support driving.
Subpack 3 state of charge (SOC) is below the threshold to support driving.
Vehicle begins end of drive ramp down.
Battery Management System Semi (BMSSEMI) detects subpack 2 state of charge (SOC) is below the threshold to support driving.
Subpack 2 state of charge (SOC) is below the threshold to support driving.
Vehicle begins end of drive ramp down.
Battery Management System Semi (BMSSEMI) detects subpack 1 state of charge (SOC) is below the threshold to support driving.
Subpack 1 state of charge (SOC) is below the threshold to support driving.
Vehicle begins end of drive ramp down.
High Voltage (HV) isolation is experiencing a fault condition.
HVPACKx_feimNeeded is true for at least one HVPACK.
Battery Management System (BMS) will exit the HV_UP state once vehicle is no longer in drive. The user will no longer be able to drive.
Battery pack 3 has pack voltage too low to allow discharge.
Battery pack 3 has pack voltage below the voltage too low limit
Drive may be blocked
Battery pack 2 has pack voltage too low to allow discharge.
Battery pack 2 has pack voltage below the voltage too low limit
Drive may be blocked
Battery pack 1 has pack voltage too low to allow discharge.
Battery pack 1 has pack voltage below the voltage too low limit
Drive may be blocked
A battery pack 3 brick voltage is below the open circuit voltage (OCV) undervoltage limit at rest.
A battery pack 3 brick voltage is below the under voltage OCV limit for X duration (in seconds) while contactors are open.
Drive may be blocked.
A battery pack 2 brick voltage is below the open circuit voltage (OCV) undervoltage limit at rest.
A battery pack 2 brick voltage is below the under voltage OCV limit for X duration (in seconds) while contactors are open.
Drive may be blocked.
A battery pack 1 brick voltage is below the open circuit voltage (OCV) undervoltage limit at rest.
A battery pack 1 brick voltage is below the under voltage OCV limit for X duration (in seconds) while contactors are open.
Drive may be blocked.
A battery pack 3 brick voltage is below the under voltage fault limit.
A battery pack 3 brick voltage is below the under voltage fault limit for X duration (in seconds)
Drive may be blocked
A battery pack 2 brick voltage is below the under voltage fault limit.
A battery pack 2 brick voltage is below the under voltage fault limit for X duration (in seconds)
Drive may be blocked
A battery pack 1 brick voltage is below the under voltage fault limit.
A battery pack 1 brick voltage is below the under voltage fault limit for X duration (in seconds)
Drive may be blocked
A battery pack 3 brick voltage is below the over discharged voltage limit.
A battery pack 3 brick voltage is below the over discharged voltage limit for X duration (in seconds)
Charge and drive may be blocked
A battery pack 2 brick voltage is below the over discharged voltage limit.
A battery pack 2 brick voltage is below the over discharged voltage limit for X duration (in seconds)
Charge and drive may be blocked
A battery pack 1 brick voltage is below the over discharged voltage limit.
A battery pack 1 brick voltage is below the over discharged voltage limit for X duration (in seconds)
Charge and drive may be blocked
A battery pack 3 brick voltage is above the fault voltage limit.
A battery pack 3 brick voltage is above the fault voltage limit for X duration (in seconds)
Power/drive limits may be reduced
A battery pack 2 brick voltage is above the fault voltage limit.
A battery pack 2 brick voltage is above the fault voltage limit for X duration (in seconds)
Power/drive limits may be reduced
A battery pack 1 brick voltage is above the fault voltage limit.
A battery pack 1 brick voltage is above the fault voltage limit for X duration (in seconds)
Power/drive limits may be reduced
A battery pack 3 brick voltage is above the warning voltage limit.
A battery pack 3 brick voltage is above the warning voltage limit for X duration (in seconds)
Power/drive limits may be reduced