Signal Name Description Condition Impact
The vehicle controller detects an undercurrent condition on the front trunk (or frunk) strut actuator, indicating the 48V rail may be down.
Firmware is commanding the frunk strut to actuate but the strut actuator draws less than 50mA for 300ms, and the velocity of the actuator is less than 1 deg/s.
The front trunk strut may be unable to actuate, preventing the front trunk from opening or closing.
The steering wheel horn switch is stuck on.
The steering wheel horn switch has been pressed for 60 seconds
The steering wheel horn switch no longer activates the horn
Steering column up / down motor end stop is not within the expected range.
The full range of up / down movement is less than 53mm or greater than 64mm.
Calibration may have been unsuccessful. Steering column profile recall may not operate as expected.
Steering column in / out motor end stop is not within the expected range.
The full range of in / out movement is less than 117mm or greater than 128mm.
Calibration may have been unsuccessful. Steering column profile recall may not operate as expected.
The bridge gate driver experienced a condition affecting its operation.
The bridge gate driver reports a condition affecting its operation.
Actuators controlled by the bridge gate driver may be inoperative.
One or more loads failed to turn on during the Left Domain Undervoltage Self-Test. Those loads will be inhibited from use in drive.
One or more loads failed to turn on during the Left Domain Undervoltage Self-Test.
Impacted load(s) will not be usable in drive.
The Left Domain Undervoltage self-test did not pass, as a condition affecting a load on the Left Domain was detected during the self-test.
The Left Domain Undervoltage self-test does not succeed.
The undervoltage protection circuit may not be functional.
Steering column thermal protection mode is activated and user input was attempted, but blocked.
Repeated steering column cycling in a short period of time
User commands for steering column are ignored until steering column motor cools
The frunk leader vehicle controller does not have a saved acceleration table, which is required for the sensitive pinch algorithm. Frunk pinch detection will not operate as expected.
The frunk leader vehicle controller does not have a saved acceleration table.
Frunk pinch detection will not function as expected.
The front trunk (frunk) current measurement dropped out during its latest motion.
The reported frunk current dropout count is non-zero.
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
No position change on frunk latch exit, so the encoder has likely stalled.
No encoder movement was seen after a latch exit
The frunk will not be able to actuate open
Horn is drawing more current than expected.
Horn current is above the expected value.
Horn(s) may not sound.
Horn is drawing less current than expected.
Horn current is below the expected value.
Horn(s) may not sound.
The frunk stopped moving for an unexpected reason.
An unexpected frunk stop reason is set
Frunk opening/closing actuation will not complete
The frunk has become uncalibrated.
The frunk latch became closed while opened at an unexpected angle
The frunk will not be able to actuate open
Frunk did not close as expected.
Frunk does not close as expected.
The frunk does not close as expected.
The upper hard stop limit for the seat backrest is disabled, meaning the seat backrest is allowed to move forward past the upper hard stop limit if requested.
The upper hard stop limit for the seat backrest is disabled.
The seat backrest is allowed to move forward past the upper hard stop limit and may interfere with the sunvisor.
The seat backrest has reached the upper hard stop limit and cannot move forward any further.
The position of the seat backrest moves forward and is above the upper hard stop limit.
The seat backrest will not move forward.
The seat track abuse has been detected, maximum number of events per time exceeded.
The maximum number of operating events per time has been exceeded
The seat track motor will be disabled
Seat track motor abuse has been detected, with number of events within 5 minutes required to generate a warning exceeded.
The number of operating events per time period required to generate a warning for seat track motor abuse has been exceeded
The seat track motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded