Alerts
Loading...
Signal Name | Description | Condition | Impact |
---|---|---|---|
The vehicle controller detects an undercurrent condition on the front trunk (or frunk) strut actuator, indicating the 48V rail may be down.
|
Firmware is commanding the frunk strut to actuate but the strut actuator draws less than 50mA for 300ms, and the velocity of the actuator is less than 1 deg/s.
|
The front trunk strut may be unable to actuate, preventing the front trunk from opening or closing.
|
|
The steering wheel horn switch is stuck on.
|
The steering wheel horn switch has been pressed for 60 seconds
|
The steering wheel horn switch no longer activates the horn
|
|
Steering column up / down motor end stop is not within the expected range.
|
The full range of up / down movement is less than 53mm or greater than 64mm.
|
Calibration may have been unsuccessful. Steering column profile recall may not operate as expected.
|
|
Steering column in / out motor end stop is not within the expected range.
|
The full range of in / out movement is less than 117mm or greater than 128mm.
|
Calibration may have been unsuccessful. Steering column profile recall may not operate as expected.
|
|
The bridge gate driver experienced a condition affecting its operation.
|
The bridge gate driver reports a condition affecting its operation.
|
Actuators controlled by the bridge gate driver may be inoperative.
|
|
One or more loads failed to turn on during the Left Domain Undervoltage Self-Test. Those loads will be inhibited from use in drive.
|
One or more loads failed to turn on during the Left Domain Undervoltage Self-Test.
|
Impacted load(s) will not be usable in drive.
|
|
The Left Domain Undervoltage self-test did not pass, as a condition affecting a load on the Left Domain was detected during the self-test.
|
The Left Domain Undervoltage self-test does not succeed.
|
The undervoltage protection circuit may not be functional.
|
|
Steering column thermal protection mode is activated and user input was attempted, but blocked.
|
Repeated steering column cycling in a short period of time
|
User commands for steering column are ignored until steering column motor cools
|
|
The frunk leader vehicle controller does not have a saved acceleration table, which is required for the sensitive pinch algorithm. Frunk pinch detection will not operate as expected.
|
The frunk leader vehicle controller does not have a saved acceleration table.
|
Frunk pinch detection will not function as expected.
|
|
The front trunk (frunk) current measurement dropped out during its latest motion.
|
The reported frunk current dropout count is non-zero.
|
This alert is primarily informational and is used for logging purposes. No expected impact on vehicle functionality.
|
|
No position change on frunk latch exit, so the encoder has likely stalled.
|
No encoder movement was seen after a latch exit
|
The frunk will not be able to actuate open
|
|
Horn is drawing more current than expected.
|
Horn current is above the expected value.
|
Horn(s) may not sound.
|
|
Horn is drawing less current than expected.
|
Horn current is below the expected value.
|
Horn(s) may not sound.
|
|
The frunk stopped moving for an unexpected reason.
|
An unexpected frunk stop reason is set
|
Frunk opening/closing actuation will not complete
|
|
The frunk has become uncalibrated.
|
The frunk latch became closed while opened at an unexpected angle
|
The frunk will not be able to actuate open
|
|
Frunk did not close as expected.
|
Frunk does not close as expected.
|
The frunk does not close as expected.
|
|
The upper hard stop limit for the seat backrest is disabled, meaning the seat backrest is allowed to move forward past the upper hard stop limit if requested.
|
The upper hard stop limit for the seat backrest is disabled.
|
The seat backrest is allowed to move forward past the upper hard stop limit and may interfere with the sunvisor.
|
|
The seat backrest has reached the upper hard stop limit and cannot move forward any further.
|
The position of the seat backrest moves forward and is above the upper hard stop limit.
|
The seat backrest will not move forward.
|
|
The seat track abuse has been detected, maximum number of events per time exceeded.
|
The maximum number of operating events per time has been exceeded
|
The seat track motor will be disabled
|
|
Seat track motor abuse has been detected, with number of events within 5 minutes required to generate a warning exceeded.
|
The number of operating events per time period required to generate a warning for seat track motor abuse has been exceeded
|
The seat track motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded
|