Alerts
Loading...
| Signal Name | Description | Condition | Impact | Important |
|---|---|---|---|---|
|
HVAC intake actuator is uncalibrated
|
Intake actuator is not calibrated
|
The heater and the A/C will be disabled
|
No
|
|
|
Electronic Parking Brake Monitor detected its motor enable line set high when it should not be.
|
Electronic Parking Brake Monitor motor enable line is set high even though it should not be given Electronic Parking Brake Monitor's current state.
|
EPB may not operate.
|
No
|
|
|
Front door latch release cam cannot find home position
|
Door latch actuator was resetting the release cam to its home position and timed out
|
Door may not be able to close
|
No
|
|
|
Glovebox voltage detected when not commanded on
|
Glovebox voltage detected in off state
|
Glovebox disabled
|
No
|
|
|
Rear door latch release cam cannot find home position
|
Door latch actuator was resetting the release cam to its home position and timed out
|
Door may not be able to close
|
No
|
|
|
The brushless motor has an integrated circuit latched fault
|
The integrated circuit has detected a condition that requires a stop
|
The HVAC cabin blower will not be able to run. The integrated circuit will be reset to attempt to clear the fault
|
No
|
|
|
HVAC LH Vane actuator faulted
|
LH Vane actuator detected a fault (check context data for type of fault)
|
The heater and the A/C and heater may be disabled
|
No
|
|
|
The motor isn't providing encoder feedback
|
Current draw is nonzero and not stalling but encoder values don't increase
|
Memory recall will be unavailable
|
No
|
|
|
Windshield washer fluid is low.
|
Washer fluid switch closed.
|
No washer fluid to wipe windshield.
|
No
|
|
|
The radiator fan brushless motor controller reports a condition affecting its operation.
|
The radiator fan motor controller reports a condition affecting the radiator fan operation.
|
The radiator fan will not be able to run.
|
No
|
|
|
HVAC blower Controller not responding on LIN
|
HVAC blower Controller not responding on LIN
|
HVAC blower Controls will not function
|
No
|
|
|
The door latch had to be rehomed because of an unexpected movement in the latch's release motor.
|
The latch is not performing a release but the home switch on the release actuator is deactivated.
|
Until this alert clears, the door latch may spontaneously release.
|
No
|
|
|
The mechanical release was used to open the door.
|
The mechanical release was used to open the door.
|
Possible damage to window trim.
|
No
|
|
|
Rear door failed to open due to latch failing to release
|
Latch state transitioned from opening to closed
|
Door will not open
|
No
|
|
|
Front door failed to open due to latch failing to release
|
Latch state transitioned from opening to closed
|
Door will not open
|
No
|
|
|
HVAC Lower Mode actuator faulted
|
Lower Mode actuator detected a fault (check context data for type of fault)
|
The heater and the A/C and heater may be disabled
|
No
|
|
|
Trunk latch failed to open
|
Trunk latch transits from opening to closed status.
|
Latch did not have enough power to release
|
No
|
|
|
Window encoder ticks not seen while the rear window motor is being driven: This suggests something is disconnected, shorted, or the controller voltage supply for the encoders is < 9V
|
Window motor is being driven and no encoder feedback is seen within 500 ms
|
Window motor is possibly disconnected or shorted
|
No
|
|
|
HVAC rear actuator faulted
|
Rear actuator detected a fault (check context data for type of fault)
|
The heater and the A/C and heater may be disabled
|
No
|
|
|
One or more of the expected CAN messages from the Etherloop Generalized Gateway Left (Core 1) were not received, indicating the EGGLEFTVC ECU may be unavailable (MIA).
|
The local ECU does not receive one or more of the expected messages from the EGGLEFTVC within the expected time frame.
|
Vehicle functions that depend on the EGGLEFTVC may be unavailable or may not function as expected.
|
No
|