Signal Name Description Condition Impact
Battery subpack 1 pyro fuse deployment was triggered by firmware.
Pyro fuse deployment was triggered by firmware.
Fast Charge (FC) link is offline and DC link is split.
Battery subpack 1 pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
Pyro fuse deployment was recently triggered and the test failed.
Pyro deployment may be compromised.
A fault condition has been detected on the battery subpack 1 pyro fuse.
Leak test failure, switch test failure, or other failure.
Pyro deployment ability is compromised.
Battery subpack 1 pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
Pyro squib is missing resulting in open-circuit resistance.
Pyro fuse deployment ability is compromised.
The High Voltage DC Link Controller (HVLINK) has detected a fault condition impacting the pyro subsystem.
A fault condition is detected by the pyro subsystem.
Pyro cannot be deployed.
The hvsense measurement Asic is not producing data.
Timeout on expected communication
HvSense readings are stale
The High Voltage DC Link Controller (HVLINK) has detected a fault condition impacting the pyro subsystem.
A fault condition is detected by the pyro subsystem.
Pyro cannot be deployed.
Negative contactor is expected to be open but HV current is still present. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
The pyro fuse may be deployed.
The High Voltage DC Link Controller (HVLINK) has detected a failure condition on the energy-reserve circuit.
Voltage, capacitance, or leakage of the energy-reserve circuit are out-of-tolerance.
Pyro deployment may be compromised.
Energy-reserve backup mode has been activated.
STANDBY_24V_INTERNAL rail is dropping due to loss of Standby power from the Subpack Controllers (SPCs).
Battery Management System Semi (BMSSEMI) and High Voltage DC Link Controller (HVLINK) are running from the onboard Energy Reserve (ER) capacitor backup power.
The HVLINK has diagnosed a short on the DC link.
The absolute value of slosh current from Bus A to Bus B on the DC Link exceeds 2000A
The FC Pyros are deployed. Fast Charge (FC) link is offline and DC link is split
Incorrect, missing, or unsupported board part number programmed.
HVLINK detects an unexpected board part number
HVLINK is unable to initialize parameters related to printed circuit board assembly (PCBA) configuration
Incorrect or missing configuration block programmed.
HVLINK config block may be missing, incorrect, or unsupported
HVLINK is unable to initialize configuration parameters
The HvSense measurement Application-specific Integrated Circuit (ASIC) has a Serial Peripheral Interface (SPI) communication error. This alert provides visibility into the health of the communications interface.
A single HvSense SPI communication error has been detected on the ASIC.
HvSenseAsicFault is at risk of being triggered soon,
VCLEFTS is not reporting to HVLINK on CAN.
VC_rcmLVState is not received by HVLINK within its mia qualification time
HVLINK shall assume VC_rcmLVState = LV_ON
The Drive Inverter (DI) High Voltage Interlock Loop (HVIL) status signal is not reporting to the High Voltage DC Link Controller (HVLINK) on the Controller Area Network (CAN).
The DI HVIL status signal is not received by HVLINK within its message cycle time.
DC Link may discharge or fail to energize.
The Drive Inverter (DI) High Voltage Interlock Loop (HVIL) is reporting as unknown, breaking the overall High Voltage DC Link Controller (HVLINK) HVIL.
The DI HVIL is reported as unknown.
DC Link may discharge or fail to energize.
The Pedal Monitor (PM) High Voltage Interlock Loop (HVIL) status signal is not reporting to the High Voltage DC Link Controller (HVLINK) on the Controller Area Network (CAN).
The PM HVIL status signal is not received by HVLINNK within its message cycle time.
DC Link may discharge or fail to energize.
The Pedal Monitor (PM) High Voltage Interlock Loop (HVIL) is reporting as unknown, breaking the overall High Voltage DC Link Controller (HVLINK) HVIL.
The PM HVIL is reported as unknown.
DC Link may discharge or fail to energize.
The Stationary Resonant Convertor (STARC) High Voltage Interlock Loop (HVIL) is reporting as unknown, breaking the overall High Voltage DC Link Controller (HVLINK) HVIL.
STARC HVIL connection is reported as unknown.
DC Link may discharge or fail to energize.