| Signal Name | Description | Condition | Impact |
|---|---|---|---|
|
Sets immediately on SPI comms errors for visibility into the health of the comms interface.
|
On single SPI comms error with the asic
|
HvSenseAsicFault is at risk of being triggered soon
|
|
|
Sets immediately on SPI comms errors for visibility into the health of the comms interface.
|
On single SPI comms error with the asic
|
ShuntAsicFault is at risk of being triggered soon
|
|
|
Warns if the pack current (discharge or charge) is above max current limit.
|
The pack current (discharge or charge) is above max current limit.
|
The pyro disconnect will blow
|
|
|
Passive pyro reference is out-of-tolerance.
|
Passive pyro reference is out-of-tolerance
|
Passive pyro fuse thresholds are affected
|
|
|
Shunt bar temperature is too high.
|
Shunt bar temperature is too high
|
Reduced accuracy and physical damage
|
|
|
Shunt thermistor is not connected.
|
Shunt thermistor reading is open-circuit
|
Subpack may not come online
|
|
|
The shunt measurement asic has a SPI communication fault or other internal fault.
|
Fault condition was set during SPI communications
|
Shunt readings are stale
|
|
|
The hvsense measurement Asic is not producing data.
|
Timeout on expected communication
|
HvSense readings are stale
|
|
|
The TCR Coefficient Calibrations are not being used.
|
The stored Shunt Bar Resistance was either invalid or the written gain was outside of tolerance.
|
The default TCR coefficients will be used. Shunt current measurement accuracy may be reduced.
|
|
|
The programmed Bar Resistance Calibration is not being used.
|
The stored Shunt Bar Resistance was either invalid or the written gain was outside of tolerance.
|
The default Shunt Bar Resistance will be used. Shunt current measurement accuracy may be reduced.
|
|
|
The programmed Shunt ASIC Calibration is not being used.
|
The stored Shunt ASIC gain was either invalid or the written gain was outside of tolerance.
|
The default Shunt ASIC gain will be used. Shunt current measurement accuracy may be reduced.
|
|
|
Hvpack is not receiving CAN messages from Hvlink.
|
Hvpack has not received a message from Hvlink in the MIA qualification time
|
Hvpack will not allow Hvlink to test the Battery Pack pyro while High Voltage is active
|
|
|
Incorrect or missing IP address programmed.
|
Hvpack IP address may be missing, incorrect, or unsupported
|
Hvpack is unable to initialize network data
|
|
|
Incorrect or missing MAC address programmed.
|
Hvpack MAC address may be missing, incorrect, or unsupported
|
Hvpack is unable to initialize network data
|
|
|
High voltage isolation is too low for the pack to be online.
|
Isolation is measured to be below the alert threshold while pack contactors are closed
|
Subpack may not come online
|
|
|
Subpack measurement of internal isolation (within the subpack) is too low.
|
Internal isolation is measured to be below the alert threshold
|
Subpack may not come online
|
|
|
The shunt measurement asic has a SPI communication fault or other internal fault.
|
Fault condition was set during SPI communications
|
Shunt readings are stale
|
|
|
The difference in pack voltage measurements of the ADC & BMBs exceeds the maximum limit.
|
The difference in ADC & BMB pack voltage is greater than 3%
|
The contactors may open immdediately or pyro disconnect may blow
|
|
|
A pack module temperature is above maximum temperature limit.
|
A pack module temperature is above maximum temperature limit for X duration (in seconds)
|
The conactors may open immdediately or pyro disconnect may blow
|
|
|
A brick voltage is below minimum voltage limit.
|
A brick voltage is below minimum voltage limit for X duration (in seconds)
|
The conactors may open immdediately or pyro disconnect may blow
|