Signal Name | Description | Condition | Impact |
---|---|---|---|
Pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
|
Pyro fuse deployment test failed
|
Pyro deployment may be compromised
|
|
A fault condition has been detected on the pyro fuse.
|
A leak test, switch test, or other type of failure is detected.
|
Pyro deployment ability is compromised.
|
|
Pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
|
Pyro squib is missing resulting in open-circuit resistance
|
Pyro fuse deployment ability is compromised
|
|
The TCR Coefficient Calibrations are not being used.
|
The stored Shunt Bar Resistance was either invalid or the written gain was outside of tolerance.
|
The default TCR coefficients will be used. Shunt current measurement accuracy may be reduced.
|
|
Pyro fuse deployment was triggered by firmware.
|
Pyro fuse deployment was triggered by firmware
|
Fast Charge (FC) link is offline and DC link is split.
|
|
Pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
|
Pyro fuse deployment was recently triggered and the deployment test failed.
|
Pyro deployment may be compromised.
|
|
A fault condition has been detected on the pyro fuse.
|
A leak test, switch test, or other type of failure is detected.
|
Pyro deployment ability is compromised.
|
|
Pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
|
Pyro squib is missing resulting in open-circuit resistance
|
Pyro fuse deployment ability is compromised
|
|
Battery subpack 3 Pyro fuse deployment was triggered by firmware but did not successfully execute.
|
Pyro fuse deployment was recently triggered and the deployment test failed.
|
Pyro deployment may be compromised.
|
|
Battery subpack 3 pyro fuse deployment was triggered by firmware.
|
Pyro fuse deployment was triggered by firmware
|
Battery subpack 3 is offline / unavailable.
|
|
Battery subpack 3 pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
|
Pyro fuse deployment was recently triggered and the deployment test failed.
|
Pyro deployment may be compromised.
|
|
A fault condition has been detected on the battery subpack 3 pyro fuse.
|
A leak test, switch test, or other type of failure is detected.
|
Pyro deployment ability is compromised.
|
|
The programmed Shunt ASIC Calibration is not being used.
|
The stored Shunt ASIC gain was either invalid or the written gain was outside of tolerance.
|
The default Shunt ASIC gain will be used. Shunt current measurement accuracy may be reduced.
|
|
Battery subpack 3 pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
|
Pyro squib is missing resulting in open-circuit resistance.
|
Pyro fuse deployment ability is compromised.
|
|
Battery subpack 2 Pyro fuse deployment was triggered by firmware but did not successfully execute.
|
Pyro fuse deployment was recently triggered and the deployment failed.
|
Pyro deployment may be compromised.
|
|
Battery subpack 2 pyro fuse deployment was triggered by firmware.
|
Pyro fuse deployment was triggered by firmware.
|
Fast Charge (FC) link is offline and DC link is split.
|
|
Battery subpack 2 pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
|
Pyro fuse deployment was recently triggered and the deployment test failed.
|
Pyro deployment may be compromised.
|
|
A fault condition has been detected on the battery subpack 2 pyro fuse.
|
A leak test, switch test, or other type of failure is detected.
|
Pyro deployment ability is compromised.
|
|
Battery subpack 2 pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
|
Pyro squib is missing resulting in open-circuit resistance.
|
Pyro fuse deployment ability is compromised.
|
|
Battery subpack 1 Pyro fuse deployment was triggered by firmware but did not successfully execute.
|
Pyro fuse deployment was recently triggered and failed to execute.
|
Pyro deployment may be compromised.
|