Alerts

Alerts

Signal Name Description Condition Impact Important
Warns if the crash signal is detected by HVP
The crash signal is detected by HVP
The pyro fuse will blow
No
A pack module temperature is above maximum temperature limit
A pack module temperature is above maximum temperature limit for X duration (in seconds)
The conactors may open immdediately or pyro fuse may blow
No
Warns if the low voltage battery is below minimum voltage threshold
The low voltage battery is below minimum voltage threshold
The contactors may not remain closed
No
A fault condition has been detected on the pyro fuse.
A leak test, switch test, or other type of failure is detected.
Pyro deployment ability is compromised.
No
Pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
Pyro squib is missing resulting in open-circuit resistance
Pyro fuse deployment ability is compromised
No
Pyro fuse deployment was triggered by firmware.
Pyro fuse deployment was triggered by firmware
Fast Charge (FC) link is offline and DC link is split.
No
Pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
Pyro fuse deployment was recently triggered and the deployment test failed.
Pyro deployment may be compromised.
No
A fault condition has been detected on the pyro fuse.
A leak test, switch test, or other type of failure is detected.
Pyro deployment ability is compromised.
No
Pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
Pyro squib is missing resulting in open-circuit resistance
Pyro fuse deployment ability is compromised
No
Battery subpack 3 Pyro fuse deployment was triggered by firmware but did not successfully execute.
Pyro fuse deployment was recently triggered and the deployment test failed.
Pyro deployment may be compromised.
No
Battery subpack 3 pyro fuse deployment was triggered by firmware.
Pyro fuse deployment was triggered by firmware
Battery subpack 3 is offline / unavailable.
No
Battery subpack 3 pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
Pyro fuse deployment was recently triggered and the deployment test failed.
Pyro deployment may be compromised.
No
A fault condition has been detected on the battery subpack 3 pyro fuse.
A leak test, switch test, or other type of failure is detected.
Pyro deployment ability is compromised.
No
Battery subpack 3 pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
Pyro squib is missing resulting in open-circuit resistance.
Pyro fuse deployment ability is compromised.
No
Battery subpack 2 Pyro fuse deployment was triggered by firmware but did not successfully execute.
Pyro fuse deployment was recently triggered and the deployment failed.
Pyro deployment may be compromised.
No
Battery subpack 2 pyro fuse deployment was triggered by firmware.
Pyro fuse deployment was triggered by firmware.
Fast Charge (FC) link is offline and DC link is split.
No
Battery subpack 2 pyro fuse deployment was recently triggered and the deployment test failed, indicating that it may not have deployed properly.
Pyro fuse deployment was recently triggered and the deployment test failed.
Pyro deployment may be compromised.
No
A fault condition has been detected on the battery subpack 2 pyro fuse.
A leak test, switch test, or other type of failure is detected.
Pyro deployment ability is compromised.
No
Battery subpack 2 pyro squib is disconnected or open-circuit, but pyro circuit is otherwise nominal.
Pyro squib is missing resulting in open-circuit resistance.
Pyro fuse deployment ability is compromised.
No
Battery subpack 1 pyro fuse deployment was triggered by firmware.
Pyro fuse deployment was triggered by firmware.
Fast Charge (FC) link is offline and DC link is split.
No