Signal Name Description Condition Impact
The programmed Bar Resistance Calibration is not being used.
The stored Shunt Bar Resistance was either invalid or the written gain was outside of tolerance.
The default Shunt Bar Resistance will be used. Shunt current measurement accuracy may be reduced.
The programmed Shunt ASIC Calibration is not being used.
The stored Shunt ASIC gain was either invalid or the written gain was outside of tolerance.
The default Shunt ASIC gain will be used. Shunt current measurement accuracy may be reduced.
Hvpack is not receiving CAN messages from Hvlink.
Hvpack has not received a message from Hvlink in the MIA qualification time
Hvpack will not allow Hvlink to test the Battery Pack pyro while High Voltage is active
Incorrect or missing IP address programmed.
Hvpack IP address may be missing, incorrect, or unsupported
Hvpack is unable to initialize network data
Incorrect or missing MAC address programmed.
Hvpack MAC address may be missing, incorrect, or unsupported
Hvpack is unable to initialize network data
High voltage isolation is too low for the pack to be online.
Isolation is measured to be below the alert threshold while pack contactors are closed
Subpack may not come online
Subpack measurement of internal isolation (within the subpack) is too low.
Internal isolation is measured to be below the alert threshold
Subpack may not come online
The difference in pack voltage measurements of the ADC & BMBs exceeds the maximum limit.
The difference in ADC & BMB pack voltage is greater than 3%
The contactors may open immdediately or pyro disconnect may blow
A pack module temperature is above maximum temperature limit.
A pack module temperature is above maximum temperature limit for X duration (in seconds)
The conactors may open immdediately or pyro disconnect may blow
A brick voltage is below minimum voltage limit.
A brick voltage is below minimum voltage limit for X duration (in seconds)
The conactors may open immdediately or pyro disconnect may blow
A brick voltage is above maximum voltage limit.
A brick voltage is above maximum voltage limit
The contactors may open immediately or pyro disconnect may blow
Incorrect, missing, or unsupported board part number programmed.
HVPACK detects an unexpected board part number
HVPACK is unable to initialize parameters related to printed circuit board assembly (PCBA) configuration
Incorrect or Missing configuration block programmed.
HVPACK config block may be missing, incorrect, or unsupported
HVPACK is unable to initialize configuration parameters
Negative contactor is expected to be open but HV current is still present. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
The pyro fuse may be deployed.
Positive contactor is expected to be open but HV current is still present. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to HV current not being low enough to open contactors.
The pyro fuse may be deployed.
Negative contactor is expected to be open but the voltage match remains. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
The pyro fuse may be deployed.
Sets immediately on SPI comms errors for visibility into the health of the comms interface.
On single SPI comms error with the asic
HvSenseAsicFault is at risk of being triggered soon
Positive contactor is expected to be open but the voltage match remains. Possible weld detected.
Contactor state timed out of OPENING (and transitioned to AUX_MISMATCH) due to a weld not having been disqualified.
The pyro fuse may be deployed.
Negative contactor is expected to be open but aux reports them as still closed.
Contactor state timed out of the OPENING state (and transitioned to AUX_MISMATCH) due to aux reporting the contactor as still closed.
Firmware will try to open the contactor again.
The shunt measurement Asic is not producing data.
Timeout on expected communication
Shunt readings are stale