HVPACK2_a006_BrickUnderVoltage
Description
A brick voltage is below minimum voltage limit.
Condition
A brick voltage is below minimum voltage limit for X duration (in seconds)
Clear Condition
All brick voltages are above minimum voltage limit
Potential Impact
The conactors may open immdediately or pyro disconnect may blow
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Semitruck